C613-50170-01 Rev B
Command Reference for x510 Series
2754
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
T
RIGGER
C
OMMANDS
SHOW
TRIGGER
To display counter information about all triggers use the command:
awplus#
show trigger counter
Figure 63-3:
Example output from the
show trigger counter
command
Type and
details
The trigger type and its activation conditions.
Days
The days on which the trigger is permitted to activate.
Date
The date on which the trigger is permitted to activate. Only
displayed if configured, in which case it replaces “Days”.
Active
Whether or not the trigger is permitted to activate.
Test
Whether or not the trigger is operating in diagnostic mode.
Trap
Whether or not the trigger is enabled to send SNMP traps.
Repeat
Whether the trigger repeats an unlimited number of times
(Continuous) or for a set number of times. When the trigger can
repeat only a set number of times, then the number of times
the trigger has been activated is displayed in brackets.
Modified
The date and time of the last time that the trigger was modified.
Number of
activations
Number of times the trigger has been activated since the last
restart of the device.
Last
activation
The date and time of the last time that the trigger was
activated.
Number of
scripts
How many scripts are associated with the trigger, followed by
the names of the script files in the order in which they run.
awplus#show trigger counter
Trigger Module Counters
------------------------------------------------------
Trigger activations ........................... 0
Time triggers activated today ................. 0
Periodic triggers activated today ............. 0
Interface triggers activated today ............ 0
Resource triggers activated today ............. 0
Reboottriggers activated today ................ 0
Ping-poll triggers activated today ............ 0
------------------------------------------------------
Table 4:
Parameters in the output of the s
how trigger full
and
show trigger
commands for a specific trigger (cont.)
Parameter
Description