C613-50170-01 Rev B
Command Reference for x510 Series
317
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
P
LUGGABLES
AND
C
ABLING
C
OMMANDS
SHOW
SYSTEM
PLUGGABLE
DETAIL
Related
Commands
show system pluggable diagnostics
Device Revision
Specifies the hardware revision code for the pluggable
transceiver. This may be useful for troubleshooting because
different devices may support different pluggable
transceiver revisions.
Device Type
Specifies the device type for the installed pluggable
transceiver.
Serial Number
Specifies the serial number for the installed pluggable
transceiver.
Manufacturing
Datecode
Specifies the manufacturing datecode for the installed
pluggable transceiver. Checking the manufacturing
datecode with the vendor may be useful when
determining Laser Diode aging issues. For more
information, see ”How To Troubleshoot Fiber and
Pluggable Issues” in the
“Getting Started with AlliedWare
Plus” Feature Overview and Configuration Guide
SFP Laser
Wavelength
Specifies the laser wavelength of the installed pluggable
transceiver.
Single Mode Fiber
Specifies the link length supported by the pluggable
transceiver using single mode fiber.
OM1 (62.5um)
Fiber
Specifies the link length (in μm - micron) supported by the
pluggable transceiver using 62.5 micron multi-mode fiber.
OM2 (50um) Fiber
Specifies the link length (in μm - micron) supported by the
pluggable transceiver using 50 micron multi-mode fiber.
Diagnostic
Calibration
Specifies whether the pluggable transceiver supports DDM
or DOM Internal or External Calibration:
Internal
is displayed if the pluggable transceiver supports
DDM or DOM Internal Calibration.
External
is displayed if the pluggable transceiver supports
DDM or DOM External Calibration.
-
is displayed if neither Internal Calibration or External
Calibration is supported.
Power Monitoring
Displays the received power measurement type, which can
be either
OMA
(Optical Module Amplitude) or
Avg
(Average Power) measured in μW.
Table 8-1: Parameters in the output from
show system pluggable detail
(cont.)
Parameter
Description