C613-50170-01 Rev B
Command Reference for x510 Series
2075
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
V
IRTUAL
C
HASSIS
S
TACKING
(VCS
TACK
™) C
OMMANDS
SHOW
COUNTER
STACK
Related
Commands
Link event
Number of link event messages.
Reinitialise
Number of reinitialize messages.
1-hop transport
Number of 1-hop transport messages.
Layer-2
transport
Number of Layer 2 transport messages.
Topology error
counters
Reasons why a neighboring unit could not join the stack.
Version
unsupported
Number of stack software version unsupported errors.
Product
unsupported
Number of product unsupported errors.
XEM unsupported
Number of XEM unsupported errors.
Too many units
Number of too many units errors.
Invalid
messages
Number of invalid messages.
Health status
good
The number of times that the resiliency link has successfully
carried healthchecks following a failure at startup.
Health status
bad
The number of times that the resiliency link healthcheck has
timed out. A timeout occurs when a backup stack member
detects a delay greater than two seconds between
healthcheck messages received.
Rx
The total number of healthcheck messages that a stack
member has received from the stack master.
Rx Error
The total number of invalid healthcheck messages that have
been received from the master. This message is not applicable
to the stack master.
Table 1:
Parameters in the output of the
show counter stack
command (cont.)
Parameters