C613-50170-01 Rev B
Command Reference for x510 Series
2215
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
G.8032 E
THERNET
R
ING
P
ROTECTION
S
WITCHING
C
OMMANDS
TRAP
(G.8032)
trap (G.8032)
Overview
Use this command to enable or disable SNMP traps for a G.8032 Ethernet Ring
Protection (ERP) instance.
Syntax
trap {enabled|disabled}
Default
The SNMP traps for the ERP instance are enabled.
Mode
G8032 Configure Switch
Usage
Globally, ERP traps are disabled by default but can be enabled globally using the
command.
Example
To disable the SNMP traps for an ERP instance named “blue”, use the following
commands:
awplus(config)#
g8032 erp-instance blue
awplus(g8032-config-switch)#
trap disabled
Related
Commands
Command
changes
Version 5.4.7-0.1: command added
Parameter
Description
enabled
Enable this ERP instance to generate traps.
disabled