INSTALLATION
XL5000
M02001102EN0319
31
4.2.2
Electrical installation
ATTENTION
Fastening the cables
The printing system can be damaged if a cable comes loose or is pulled out when the printing system is
switched on. The manufacturer assumes no warranty and liability for the resulting damage.
▪
You may not insert or pull out any cables from the printing system when the printing system is
switched on.
▪
Ensure that all cables are firmly screwed down on the printing system before you switch on the
printing system.
▪
Establish connection with the host machine via the I/O interface of the printing system
Please observe that the cable used to connect the printing system to the host machine must be appropriately screened
for safe operation and that the maximum permissible length defined in "
Mechanical
data
" may not be exceeded.
NOTE
Power rating of the outputs “Free / Busy”
and “On cycle / Printed”:
The following limits for the outputs must not be exceeded:
U
max.
= ± 240 V
I
max.
= 80 mA