CLEANING AND MAINTENANCE
60
XL5000
M02001102EN0319
7.2.6
Pneumatic connection
If it is necessary to replace components in the scope of maintenance or repairs that have a pneumatic connection,
please refer to the following schematic diagrams. The specified diameters refer to the outside diameter of the hoses.
①
Pneumatic connection: air in
–
solenoid valves
(Ø 6 mm)
③
Pneumatic connection: print stroke (Ø 3 mm)
②
Pneumatic connection: pre- stroke (Ø 3 mm)