Rockwell Automation Publication 1407-UM001H-EN-P - November 2014
#HAPTER
CGCM Unit Software Interface
#'#-5NIT$ATA4ABLE3UMMARY
This table summarizes what information the data tables provide.
#'#-5NIT5SER0ROGRAM
)NTERFACE
The CGCM unit and the ControlLogix controller transfer data through five
controller tags based on the module-defined data types listed in the
Summary of
Data Tables
.
When the CGCM unit is added into the RSLogix 5000 software project,
RSLogix 5000 software creates the five module defined data types. In addition,
four controller tags are created by using these data types:
•
[CGCM_Module_Name]:C
, the Configuration tag
•
[CGCM_Module_Name]:C.UnschWrite
, the Unscheduled Write tag
•
[CGCM_Module_Name]:O
, the Output or Scheduled Write tag
•
[CGCM_Module_Name]:I
, the Input or Scheduled Read tag
When the Configuration tag is created, a set of default values are assigned. These
default values do not always reflect the configuration parameters necessary for
operation of your application.
Refer to
Chapter 4
for information on configuring the CGCM unit with the
RSLogix 5000 software module configuration dialog boxes.
4ABLE3UMMARYOF$ATA4ABLES
$ATA4
ABLE.AME
&IRMWA
RE2EVISION
$
ATA!CC
ESS
-OD
ULEDEFINED$ATA
4Y
PE
!S
S
Y)NSTANCE
3IZE"YTES
-ESSA
GE4
YPE
7
RITEPERMITTED
WITH
%XCITATION%NABLED
2EFER
TO
0AGE
Input (Scheduled
Read)
N/A
R
AB:1407_CGCM:I:0
2
76
S
N/A
134
Output (Scheduled
Write)
2.
X
W
AB:1407_CGCM:O:0
1
56
S
Y
138
3.
X
/4.
X
AB:1407_CGCM:O:1
Unscheduled Read
2.
X
R
AB:1407_CGCM: Unscheduled_Read
5
172
U
N/A
142
3.
X
/4.
X
AB:1407_CGCM: Unscheduled_Read3
Unscheduled Write
2.
X
W
AB:1407_CGCM: Unscheduled_Write
6
64
U
Y
144
3.
X
/4.
X
AB:1407_CGCM: Unscheduled_Write3
76
Configuration
2.
X
R/W
AB:1407_CGCM:C:0
4
344
S (W)
U (R)
N
147
3.
X
/4.
X
(1)
AB:1407_CGCM:C:1
(1) Series C units with ControlNet Daughter Card firmware revision 1.09 or later and Series D units have an additional instance that can be used to access this data. The
assembly instance is 7 and the size is 352. This instance eliminates the need for the user to deal with internal bytes used by RSLogix software.
(2) S = Scheduled, U = Unscheduled, W = Write, R = Read.
Summary of Contents for 1407-CGCM
Page 1: ...Combination Generator Control Module Catalog Numbers 1407 CGCM User Manual...
Page 4: ...Rockwell Automation Publication 1407 UM001H EN P November 2014 3UMMARY OF HANGES OTES...
Page 8: ...Rockwell Automation Publication 1407 UM001H EN P November 2014 0REFACE OTES...
Page 12: ...Rockwell Automation Publication 1407 UM001H EN P November 2014 HAPTER General Information OTES...
Page 70: ...Rockwell Automation Publication 1407 UM001H EN P November 2014 HAPTER CGCM Unit Operation OTES...
Page 126: ...Rockwell Automation Publication 1407 UM001H EN P November 2014 HAPTER CGCM Unit Startup OTES...
Page 168: ...Rockwell Automation Publication 1407 UM001H EN P November 2014 HAPTER Troubleshooting OTES...
Page 212: ...Rockwell Automation Publication 1407 UM001H EN P November 2014 PPENDIX Specifications OTES...
Page 250: ...Rockwell Automation Publication 1407 UM001H EN P November 2014 NDEX OTES...
Page 251: ......