this threshold, a single threshold crossing event will be generated. A single threshold crossing event
will also be generated if the first sample taken is less than or equal to this threshold and the associated
startup-alarm is equal to falling or either.
After a falling threshold crossing event is generated, another such event will not be generated until the
sampled value rises above this threshold and reaches greater than or equal the rising-threshold value.
Default
0
Values
-2147483648 — 2147483647
interval seconds —
Specifies the polling period, in seconds, over which the data is sampled and compared
with the rising and falling thresholds.
Values
1 — 2147483647
rmon-event-type
—
Specifies the type of notification action to be taken when this event occurs.
Values
log — An entry is made in the RMON-MIB log table for each event occurrence. This does
not create a TiMOS logger entry. The RMON-MIB log table entries can be viewed using
the
show>system>thresholds
CLI command.
trap — A TiMOS logger event is generated. The TiMOS logger utility then distributes the
notification of this event to its configured log destinations which may be CONSOLE, tel-
net session , memory log, cflash file, syslog, or SNMP trap destinations logs.
both — Both a entry in the RMON-MIB logTable and a TiMOS logger event are gener-
ated.
none — No action is taken.
Default
both
startup-alarm alarm-type —
Specifies the alarm that may be sent when this alarm is first created.
If the first sample is greater than or equal to the rising threshold value and startup-alarm is equal to
rising or either, then a single rising threshold crossing event is generated.
If the first sample is less than or equal to the falling threshold value and startup-alarm is equal to falling
or either, a single falling threshold crossing event is generated.
Default
either
Values
rising, falling, either
Configuration example:
cflash-cap-alarm cf1-A: rising-threshold 50000000 falling-threshold 49999900 interval 120 rmon-
event-type both start-alarm rising.
Summary of Contents for 7950 XRS Series
Page 8: ...Page 8 7950 SR OS Basic System Configuration Guide List of Tables...
Page 10: ...Page 10 7950 SR OS Basic System Configuration Guide List of Figures...
Page 14: ...Preface Page 14 7950 SR OS Basic System Configuration Guide...
Page 46: ...VI Editor Page 46 7950 SR OS Basic System Configuration Guide...
Page 76: ...File Management Tasks Page 76 7950 SR OS Basic System Configuration Guide...
Page 78: ...File Command Reference Page 78 7950 SR OS Basic System Configuration Guide...
Page 172: ...Basic CLI Commands Page 172 7950 SR OS Basic System Configuration Guide...
Page 184: ...Configuration Notes Page 184 7950 SR OS Basic System Configuration Guide...
Page 214: ...DNS Configuration Commands Page 214 7950 SR OS Basic System Configuration Guide...
Page 220: ...Show Commands Page 220 7950 SR OS Basic System Configuration Guide...
Page 494: ...System Commands Page 494 7950 SR OS Basic System Configuration Guide...
Page 500: ...Standards and Protocols Page 500 Standards and Protocols...