Configuring Timing References
Use the following CLI syntax to configure timing reference parameters. Note that the source port
specified for
ref1
and
ref2
cannot both be from the same slot.The following displays a timing
reference configuration example:
ALA-12>config>system>sync-if-timing# info
----------------------------------------------
ref-order
ref2 ref1 bits
ref1
source-port
3/1/1
no shutdown
exit
ref2
source-port
6/1/2
no shutdown
exit
bits
interface-type ds1 esf
no shutdown
exit
----------------------------------------------
ALA-12>config>system>sync-if-timing#