Sensor Base Assy.
1. Apply Loctite Purple to a degreased Tapped Screw 2 x 4 to secure a Sensor Board D Unit to a
Sensor Base.
2. Similarly, secure a Sensor Board E unit to the Sensor Base.
(Tightening torque: 10-20 cN.m)
Note) Be careful not to assemble the Sensor Boards the other way around.
Torque should be controlled after confirming that a Screw Head has seated on the board.
ASSEMBLY PROCEDURE
TORQUE ADHESIVE
10-20 cN.m
Loctite Purple
RB70081
(SENSOR BOARD E UNIT)
RB10765
(SENSOR BASE)
RB70080
(SENSOR BOARD D UNIT)
Apply Loctite Purple.
After degreasing;
If properly assembled, the topside
will be flush.
AA31714
(TAPPED SCREW 2 x 4)
AA31714
(TAPPED SCREW 2 x 4)