Display Control
To speed up your measurement rate, or for security reasons, you may
want to turn off the front-panel display. From the remote interface, you
can also display a 11-character message on the front panel.
See page 43
for information about the number of digits displayed.
•
When the display is turned off, readings are not sent to the display
and all display annunciators except
‘ERROR’
and
‘Shift’
are disabled.
Front-panel operation is otherwise unaffected by turning off the
display.
•
The display state is stored in
volatile
memory; the display is enabled
when power has been off or after a remote interface reset.
•
You can display a message on the front panel by sending a command
from the remote interface. The meter can display up to 11 characters
of the message on the front panel; any additional characters are
truncated. Commas, periods, and semicolons share a display space
with the preceding character, and
are not
considered individual
characters. When a message is displayed, readings are not sent to the
display.
•
Sending a message to the display from the remote interface overrides
the display state; this means that you can display a message even if
the display is turned off.
•
Front-panel operation:
set the display state under the
5: DISPLAY
command in the SYStem menu.
The display always turns on for menu operation; this means that even
when the display is turned off, you can still operate the menu.
•
Remote operation:
use the following commands to control the
display:
DISPlay {OFF|ON}
DISPlay:TEXT <
quoted string
>
DISPlay:TEXT:CLEar
disable/enable the display
display the string
enclosed in quotes
clear the message in the
display
The following statement shows how to display a message on the front
panel from a Hewlett-Packard controller.
OUTPUT 722; "DISP:TEXT ’HELLO’"
Chapter 3 Features and Functions
System-Related Operations
94
Summary of Contents for 34420A
Page 1: ......
Page 2: ......
Page 13: ...1 Quick Start ...
Page 31: ...2 Front Panel Operation ...
Page 55: ...3 Features and Functions ...
Page 117: ...4 Remote Interface Reference ...
Page 200: ...5 Error Messages ...
Page 213: ...6 Application Programs ...
Page 245: ...6 Chapter 6 Application Programs Microsoft Excel Macro Example 245 ...
Page 246: ...Chapter 6 Application Programs Microsoft Excel Macro Example 246 ...
Page 247: ...7 Measurement Tutorial ...
Page 274: ...8 Specifications ...
Page 279: ...Dimensions Chapter 8 Specifications 34420A Nano Volt Micro Ohm Meter 280 ...
Page 294: ......