42
Futuresun HP V2
For assembly of the second exhaust air stack
follow the same procedure.
Positioning of unit at site of
installation
If the floor at the site of installation is uneven, the unit
has to be adjusted to a level position with the provided
adjusting screws. Proceed as follows:
Move the unit to the final place of installation.
Position the unit in such a way that on
each side there is a minimum distance of
10” to the walls.
Push the adjusting screws in or out until the unit is
in an approximate level position.
Use a water level to determine final level position.
Assembly of condensation water
container onto assembly plate
for SunFresh /condensation water
assembly plate
The condensation water container receives the
condensation water from the AC unit. The water level
is controlled by a water level indicator. If the maximum
water level for the condensation water container is
reached, the display on the control panel shows the
message “E 07”. The condensation water container
is put into a holder inside the sunbed and with a hose
connected to the condensation waterpump. The water
pump is located close to the AC unit.
Put the container in such a way into the holding
device that it touches the water level indicator (1).
First Start-Up
Prior to first starting the sunbed, make sure that all set
ups are correct and all safety features are installed,
for example:
sunbed acrylic
top canopy acrylic
High pressure filter glasses
on-site exhaust air disposal into the open
sufficient fresh air supply of minimum 2600cfm, for
instance a big window or an air duct.
function of emergency stop button
Summary of Contents for Future Sun HP
Page 72: ...72 Futuresun HP V2 ...
Page 73: ...73 Futuresun HP V2 ...