18-9
CLASS 2 PLUG-IN
TRANSFORMER
16.5V
A
C
, 25V
A
(e
.g.
ADEMCO No
. 1321).
(USE No
. 1321CN IN CANAD
A)
T
O
110V
A
C
UNSWITCHED
OUTLET (24HR)
THIS EQ
UIPMENT SHOULD BE INST
ALLED
IN A
CCORD
ANCE
WITH
THE NA
TIONAL
FIRE PR
O
T
ECTION ASSOCIA
TION'S
ST
AND
ARD 72, CHAPTER 11 (NA
TIONAL
FIRE PR
O
TECTION ASSOCIA
TION,
B
A
T
T
E
R
Y
-MARCH P
ARK, Q
U
INCY
,MA
02169).
PRINTED INFORMA
TION
DESCRIBING P
R
OPER INST
ALLA
TION,
OPERA
TION,
TESTING, MAINTENANCE,
E
V
A
C
U
A
T
IO
N
PLANNING AND REP
A
IR
SER
VICE IS
T
O
B
E
P
R
O
VIDED WITH
THIS
EQ
UIPMENT
.
24-HR B
A
TTER
Y ST
ANDBY REQ
UIRED FOR
FIRE INST
ALLA
TIONS.
USE 12V
, 17.2AH
B
A
TTER
Y FOR 600mA A
UX PO
WER.
SEE
INSTR
UCTIONS.
B
A
TTER
Y CAP
A
CITY FOR EMERGENCY
B
URGLAR
Y ST
ANDBY USE A
T
LEAST 4 HRS
USE UL LISTED LIMITED ENERGY
CABLE FOR ALL CONNECTIONS
USE 1361X10
TRANSFORMER
INTERF
A
C
E
IN PLA
CE OF 1321 OR
1321CN
WHEN PO
WER LINE CARRIER
DEVICES ARE BEING USED
. (SEE
INSTR
UCTIONS FOR CONNECTIONS)
**FOR COMPLETE INFORMA
TION,
SEE INSTR
UCTIONS K5305V3
OR LA
TER.
ALARM OUTPUT
10.5
–
13.8VDC
, 2A MAX.
(600mA MAX.
FOR UL
USA
GE, INCLUDING
A
UX PO
WER) STEAD
Y
FOR B
URGLAR
Y/P
ANIC
,
TEMPORAL PULSE
SOUNDING FOR FIRE.
CAN USE ADEMCO
No
. 702 SIREN, OR
12V BELL.
SEE
INSTR
UCTIONS**.
CHARGING V
O
LT
A
G
E
13.8VDC
. MAXIMUM
CHARGING CURRENT
650mA.
B
A
TTER
Y
12V
, 4AH
+
+
BLA
CK
RED
SEALED LEAD-A
C
ID
TYPE.
BA
TTER
Y NORMALL
Y NEED NO
T BE
REPLA
CED FOR A
T
LEAST 3
YRS
.
T
O
DETERMINE
T
O
T
AL ST
ANDBY LO
AD
ON BA
TTER
Y
, ADD 100mA
T
O
T
O
T
AL OF
A
UX.
PO
WER OUTPUT AND REMO
TE
T
OUCHP
AD CURRENTS
.
CONNECTION OF
THE FIRE ALARM
SIGNAL
T
O
A FIRE ALARM
HEADQ
U
A
R
TERS OR A CENTRAL ST
A
TION
SHALL BE PERMITTED ONL
Y
WITH
THE
PERMISSION OF
THE LOCAL A
UTHORITY
HA
VING JURISDICTION.
THE B
URGLAR
ALARM SIGNAL SHALL NO
T BE
CONNECTED
T
O
A POLICE EMERGENCY
NUMBER.
OPTIONAL
FOR UP TO
40 ADDITIONAL ZONES
( FROM EITHER OR BO
TH GROUPS)
BLK
RED
GRN
YEL
7
21
22
23
24
25
EAR
TH
GR
OUND
SEE
INSTR
UCTIONS**
FOR PR
OPER
GR
OUNDING
TELEPHONE WIRING
(VIA RJ31X* J
A
CK AND DIRECT CONNECT CORD) *CA38A IN CANAD
A
DOC LO
AD NO
.:
3
RED: T
OUCHP AD PWR (
+
)
GREEN: D
A TA
IN FROM
TOUCHP
AD
YELLOW:
T
OUCHP
AD DA
T A
OUT
BLK
RED
GRN
YEL
T
O
TERM
4
T
O
TERM
5
T
O
TERM
6
T
O
TERM
7
BLK
RED
GRN
YEL
RING
(GRA
Y)
TIP
(GREEN)
RING
(RED)
INCOMING
PHONE LINE
HANDSET
ZONE 1
ZONE 2
HI
LO
HI
LO
ZONE 4
HI
LO
HI
LO
ZONE 5
ZONE 6
ZONE 7
ZONE 8
•
MAX.
LOOP RESIST
ANCE:
(EA
CH ZONE)
300 OHMS (PLUS EOLR)
•
•
RESPONSE,
ZONES 1-8:
10, 350,
OR 700 MSEC (PR
OGRAMMABLE)
8-PIN CONNECT
OR
USED FOR 1361X10
TRANSFORMER
CONNECTIONS AND FOR
ON-BO
ARD TRIGGERS
SEE INSTR
UCTIONS
.
78
(USE SA4120XM-1
CABLE)
TIP
(BR
O
WN)
}
}
COMPLIES
WITH FCC R
U
LES
, P
A
R
T
68.
FCC REGISTRA
TION
NO
. 5GB
U
SA-44003-AL-E RINGER EQ
UIV
ALENCE:
0.1B
.
WEEKL
Y
TESTING IS REQ
UIRED
T
O
ENSURE PR
OPER
OPERA
TION OF
THIS SYSTEM.
IN ADDITION,
THIS
SYSTEM MUST BE CHECKED BY A Q
U
ALIFIED
TECHNICIAN A
T
LEAST ONCE EVER
Y
THREE (3)
YEARS.
CAN BE USED FOR 2-WIRE SMOKE DETECTO
RS
RED JUMPER
CUT FOR BELL SUPER
VISION.
ALSO
, CONNECT 2000 OHM RESIST
OR
DIRECTL
Y A
C
R
OSS SOUNDER.
FOR CONNECTION OF OPTIONAL
4286
VIP MODULE
T
O
PHONE
TERMINALS
, SEE INSTR
UCTIONS
.**
REMO
TE T
OUCHP
ADS
EA
CH P
A
R
T
ITION CAN
USE 6150ADT OR 6160ADT
T
OUCHP
ADS
. SEE
INSTR
UCTIONS PR
O
V
IDED
WITH T
OUCHP
AD
. LOCAL
PR
OGRAMMING MUST BE
DONE
WITH A 6160ADT
B
UT NEED NO
T REMAIN
IN THE
SYSTEM
(SET
T
O
ADDRESS 16).
2000
OHMS
EOLR
SAFEW
A
TCH PR
O 3000EN
ENTREPRENEUR 3000EN
SECURITY MANA
GER 3000EN
SUMMAR
Y
OF CONNECTIONS
SYNC
COM
DA
T
A
TO
TRANS
.
GND
+12 AU
X
10
9
6
12
3
4
5
6
OUTPUT 18
(TRIG. 2)
OUTPUT 17
(TRIG. 1)
ALL DEVICES AND
A
CCESSORIES
USED IN A CANADIAN
INST
ALLA
T
ION MUST BE
LISTED FOR USE IN
CANAD
A
3A
SET
RECEIVER
’S
DIP SWITCH
FOR DEVICE
ADDRESS
OF
“0
”.
SEE
INSTR
UCTIONS
.
SET UNIT
’S
DIP SWITCH
FOR DEVICE
ADDRESSES
7 - 15.
SEE
INSTR
UCTIONS
.
MAXIMUM NUMBER OF 2-WIRE SMOKE
DETECT
ORS ON ZONE 1 IS 16;
DETECT
ORS MUST HA
VE COMP
A
TIBILITY
IDENTIFIER AS "A".
PO
WER SHUTDO
WN NO
TE:
SYSTEM SHUTS DO
WN
SENSOR DETECTION
PR
OCESSING IF CONTR
O
L'S
V
O
LT
A
GE DR
OPS BELO
W
9.6V
.
4-WIRE SMOKE DETECT
OR CONNECTIONS
+
+
2000
OHMS
EOLR
HEA
T
DETECT
O
R
RED
EOL
PO
WER
SUPER
VISION
RELA
Y
MODULE
A77-716B
.
USE N.O
.
CONT
A
CT
,
WHICH CLOSES
WHEN PO
WER
IS APPLIED
.
VIOLET
A
UX PWR
OUTPUT
TERMINALS
5
4
_
_
+
BLK
_
T
O
ZONE
TERM.
( )
T
O
ZONE
TERM.
( )
RELA
Y
CONT
A
C
T OPENS MOMENT
A
RIL
Y
UPON FIRE ALARM RESET
PR
OGRAM RELA
Y
AS ZONE
TYPE 54
(FIRE ZONE RESET)
_
+
4-WIRE SMOKE
OR COMB
USTION
DETECT
O
R
N.C
.
N.O
.
T
O
OUTPUT 17
PR
OGRAM OUTPUT 17 FOR
"OUT NORM LO
W" =
YES IN
79 MENU MODE AND AS ZONE
TYPE 54 IN 80 MENU MODE
MAX.
CURRENT = 100 mA
OR
ADEMCO 5881*
T
ype
RF RECEIVER
WIRELESS ZONES
*5882 IN CANAD
A
ADEMCO No.
4219
WIRED EXP
ANSION MODULE
(8 ADD'L EOLR
WIRED ZONES)
-OR-
ADEMCO No.
4229
WIRED EXP
ANSION/RELA
Y MODULE
(8 ADD'L EOLR
WIRED ZONES PLUS 2
OUTPUT RELA
YS)
-OR-
ADEMCO No.
4204 RELA
Y MODULE
(4 OUTPUT RELA
YS)
AND/OR
5881L:
UP
T
O
8
5881M:
UP
T
O
16
5881H:
UP
T
O
64 (48+16 B
UTT
ONS)
BLACK:
T
OUCHP AD GR
OUND (- ) RETURN
NO
TE:
T
OUCHP
ADS (S)
CURRENT (IN
BO
TH
P
A
R
TITIONS)
AND ALL
O
THER DEVICES
DRA
WING
PO
WER FR
OM
TERMS 4 & 5
MUST BE
INCLUDED IN
A
UX CURRENT
DRAIN
CALCULA
TIONS
.
A
UX.
PO
WER
OUTPUT
10.5-13.8VDC
600mA MAX.
(500mA MAX.
FOR UL
INST
ALLA
TIONS)
ALL OUTPUTS
ARE PO
WER
LIMITED
.
+
}
BLK
5
REMO
TE
T
OUCHP
ADS
AND O
THER
ADDRESSABLE
DEVICES
(e
.g.
5800TM,
4285/4286,
LRR,
4219,
4229,
4204,
5881)
(USE EOLR P
A
R
T
NUMBER P4100,
P
A
R
T
OF KIT SAHD
WR1)
**
**
**
**
CIRCUIT
(ZONE)
CONTR
OL UNIT
DELA
Y
-SEC
SMOKE DETECT
O
R
MODEL DELA
Y
-SEC
USE
THE DELA
Y
TIME MARKED ON
THE INST
ALLED
DETECT
OR(S).
W
ARNING:
ALARM
VERIFICA
TION, IF USED
, DELA
Y
S
ALARM SIGNALS FR
OM
THE INDICA
TED FIRE
CIRCUITS
. DO NO
T EXCEED 60 SECONDS OF
T
O
T
A
L
DELA
Y (CONTR
OL UNIT PLUS SMOKE DETECT
ORS).
DO NO
T CONNECT O
THER INITIA
TING DEVICES
T
O
THESE CIRCUITS UNLESS APPR
O
VED BY
THE
LOCAL A
UTHORITY HA
VING JURISDICTION.
12
3
4
ZONE 3
HI
LO
HI
LO
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
8
11
12
14
13
HI
LO
HI
LO
17
16
15
20
18
19
FL
YING LEADS
FOR BA
TTER
Y
CONNECTION
Zn 1 Output 17
7 secs 3 secs
W
A
RNING:
T
O
PREVENT RISK OF SHOCK,
DISCONNECT TELEPHONE
LINE
A
T
TELCO
J
A
CK BEFORE SER
VICING
THIS UNIT
.
B
A
TTER
Y FUSE
(IF INST
ALLED)
FOR REPLA
CEMENT
,
USE SAME
V
ALUE
(e
.g.
ADEMCO No
. 90-12)
FUSE NO
TE
MA
Y HA
VE PTC IN
PLA
CE OF FUSE.
SW3000EN-SOC-V0
Summary of Contents for Enterpreneur 3000EN
Page 64: ...3000EN Series Installation Instructions 6 6...
Page 68: ...3000EN Series Installation Instructions 8 2...
Page 78: ...3000EN Series Installation Instructions 12 2...
Page 82: ...13 4...
Page 88: ...3000EN Series Installation Instructions 14 6...
Page 92: ...3000EN SERIES INSTALLATION INSTRUCTIONS 15 4...
Page 96: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 2 NOTES...
Page 97: ...17 3 NOTES...
Page 98: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 4 NOTES...