Mounting and Wiring the Control
2-21
Using the AVS System with AVS-ADT Module and AVST-ADT Remote Stations
The AVS system provides audio alarm verification via the phone line or via AlarmNet if the
GSMV-ADT module is used as the communication device.
Refer to the instructions included with the AVS-ADT system for installation procedures. The
following is a summary.
Mounting the AVS-ADT Base Unit
As shipped, the AVS-ADT Base unit board comes pre-
mounted on its mounting bracket, which is designed to
mount inside the control cabinet.
Refer to the diagram at right.
a. Position the mounting plate/PC board assembly in
the bottom of the control’s cabinet.
b. Slide the mounting plate to the right so that the
plate’s left-hand tang slides under the cabinet’s tie-
wrap loop.
c. Secure the assembly to the cabinet using the two
self-tapping screws provided.
AVS-003-V0
SYSTEM
BATTERY
2
3
5
1
ON
4
2
3
1
ON
4
TANG
BENEATH
MOUNTING
PLATE
SECURE
WITH TWO (2)
SELF-TAP SCREWS
(SUPPLIED)
SLIDE ASSEMBLY TO RIGHT UNTIL
TANG SLIPS UNDER CABINET LOOP
CABINET
TIE-WRAP
LOOP
BATTERY NOTE:
When using a 7AH battery, mount the battery vertically on the bottom left-hand
side of the cabinet, with the terminals facing down and right (negative terminal closest to the PC
board bracket).
Wiring the AVS-ADT to the Control
The AVS-ADT Base unit board has several terminal blocks for making connections to remote stations,
telephone lines, and to the control panel. The AVS-ADT base unit connects to the control’s ECP
terminals, with all other ECP devices connecting to the AVS-ADT base unit ECP terminals. See the
diagram on the next page for specific wiring connections.
DIP Switch:
Set the AVS DIP switch to the address 11.
IMPORTANT:
The AVS-ADT should be the only ECP device connected to the control’s ECP
terminals. Connect all other ECP devices (touchpads, expander modules, etc.) to the ECP
terminals on the AVS board.
Connecting an Optional GSMV Module
a. If using a GSMV module for 2-way voice operation, install the module according to its instructions.
NOTE:
The module must be mounted within three feet of the control.
b. Connect the audio cable from the GSMV module to the Audio connector on the AVS board. The
audio cable is supplied with the GSMV module.
c. Complete all other GSMV wiring following the instructions included with that module.
The following summarizes the programming steps for AVS operation (refer to the Programming Guide
for details of the AVS Quick Command options):
a. Install the AVS module according to its instructions.
b. Use one of the control’s AVS Quick Program commands as follows :
•
installer code + [#] + 03:
enable AVS operation without panel sounds on the AVST
•
installer code + [#] + 04:
enable AVS operation and enable panel sounds on the AVST speaker
c. Use data field
∗
55 Dynamic Signaling Priority to select the desired reporting paths.
Summary of Contents for Enterpreneur 3000EN
Page 64: ...3000EN Series Installation Instructions 6 6...
Page 68: ...3000EN Series Installation Instructions 8 2...
Page 78: ...3000EN Series Installation Instructions 12 2...
Page 82: ...13 4...
Page 88: ...3000EN Series Installation Instructions 14 6...
Page 92: ...3000EN SERIES INSTALLATION INSTRUCTIONS 15 4...
Page 96: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 2 NOTES...
Page 97: ...17 3 NOTES...
Page 98: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 4 NOTES...