Mounting and Wiring the Control
2-5
Wiring the AC Transformer
1321 Transformer
Connect the 1321 Transformer to terminals 1 and 2 on the control board. See Wire Run Chart below
for wire size to use. Use 1321CN in Canada.
1361X10 Transformer
(required if using Powerline Carrier devices)
1. Splice one end of a 3-conductor cable to the wire ends of the SA4120XM-1 Cable.
2. Connect the SA4120XM-1 cable plug to the 8-pin connector on the control (see the Summary of
Connections diagram for location of the 8-pin connector).
3. Connect the other end of the 3-conductor cable to the 1361X10 Transformer, as shown.
Canada:
See Powerline Carrier Device section for connections to the PSC04 X-10 Interface and
trigger pins.
Notes
•
Use caution when wiring the transformer to the control to guard against blowing the transformer
fuse (the fuse is non-replaceable).
•
Wiring to the AC transformer must not exceed 250 feet using 16 gauge wire. The voltage level
between terminals 1 and 2 of the control must not fall below 16.5VAC or else an “AC LOSS”
message will be displayed.
•
Do not plug the transformer into the AC outlet while making any wiring connections to the control.
As a safety precaution, always power down the control when making such connections.
Wire Run Chart
Distance from control Wire Size
Up to 50 feet
# 20
50–100 feet
# 18
100-250 feet
# 16
AC
AC
SYNC COM
DATA
2
3
4
5
1
2
1
SA412OXM-1
CABLE
CONTROL
BOARD
TERMS.
1361X10 TRANSFORMER
00-tr
igcon-001-V2
1
3
4
5
6
7
8
8-PIN TRIGGER CONNECTOR
KEY
+12 A
UX.
D
ATA
COM
SYNC
GND (-)
OUTPUT 17
(RED)
OUTPUT 18
(GREEN)
(ORANGE)
(YELLO
W)
(BLUE)
(PURPLE)
(BLA
CK)
Figure 4. 1361X10 Transformer Connections
Summary of Contents for Enterpreneur 3000EN
Page 64: ...3000EN Series Installation Instructions 6 6...
Page 68: ...3000EN Series Installation Instructions 8 2...
Page 78: ...3000EN Series Installation Instructions 12 2...
Page 82: ...13 4...
Page 88: ...3000EN Series Installation Instructions 14 6...
Page 92: ...3000EN SERIES INSTALLATION INSTRUCTIONS 15 4...
Page 96: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 2 NOTES...
Page 97: ...17 3 NOTES...
Page 98: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 4 NOTES...