6-1
S E C T I O N 6
Output Device Programming
(*79/*80 Menu Mode)
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About Output Device Programming
Output Devices:
The system supports up to 16 relays and/or Powerline Carrier devices (X-10
devices) plus 2 built-in trigger outputs in any combination. These 18 “outputs”
are assigned to system-wide output numbers (01-18). Use *79 Menu Mode to
assign output numbers and map them to device addresses.
Output Functions:
The system also provides up to 48 installer-defined output functions, which can
be assigned to any of the 18 physical outputs. Therefore, the action of any one of
the 18 outputs can be based on as many of these defined functions as desired.
This lets a single relay or X-10 device perform many functions. Use *80 Menu
Mode to define output functions.
Relays and output devices are not recommended for life safety applications.
NOTE:
When navigating the *79 and *80 menus: The [
✱
] key is used to accept an entry and advance to the next
prompt. The [#] key is used to revert back to the last question to check or change an entry. Press [
✱
] to go
forward again.
Output Device programming involves:
1. Use *79 Menu Mode to assign module and output numbers and map them to device addresses.
NOTE:
You must map output devices using *79 Menu Mode
before
you can use *80 menu Mode).
2. Use *80 Menu Mode to create up to 48 output definitions, which control the output devices.
*79 Menu Mode: Output Device Mapping
Use this menu to assign Relay Module device addresses and specific relay numbers, and Powerline
Carrier unit numbers. The system is based on predefined module addresses for 4204 and 4229 modules.
Refer to the table shown at the “Module Address” prompt on the next page and set the modules’
addresses (via module DIP switches) accordingly.
The following table shows how these outputs are identified.
Output Identification
This output…
is identified by…
Relays:
the Relay Module’s device address and the relay position on that module (i.e. the
physical relay number, 1-4, on that module).
X-10 Device
a house ID (entered in data field *27) and the unit number of the device.
Built-in Outputs
the output number assigned, 17 for Trigger 1 and/or 18 for Trigger 2.
Summary of Contents for Enterpreneur 3000EN
Page 64: ...3000EN Series Installation Instructions 6 6...
Page 68: ...3000EN Series Installation Instructions 8 2...
Page 78: ...3000EN Series Installation Instructions 12 2...
Page 82: ...13 4...
Page 88: ...3000EN Series Installation Instructions 14 6...
Page 92: ...3000EN SERIES INSTALLATION INSTRUCTIONS 15 4...
Page 96: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 2 NOTES...
Page 97: ...17 3 NOTES...
Page 98: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 4 NOTES...