background image

EX-CSS 180

Operating instructions

Safety sensor

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. the operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, labelled with the caution or warning symbol above, 

the country-specific installation standards as well as all prevailing safety 

regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.3  Switching distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.4  Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4  Rear side Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .4

4.2  Connection example  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4.3  Series wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4.4  Wiring example  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

4.5  Note on the total length of a safety sensor chain. . . . . . . . . . . . . . .5

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6  Diagnostic functions

6.1  Operating principle of the diagnostic LED's . . . . . . . . . . . . . . . . . . .6

6.2  Operating principle of the electronic diagnostic output  . . . . . . . . . .6

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

8  EU Declaration of conformity

x.000 / 1

1.2017 / v

.A.   -   101

189309-EN / E / 2017-1

1-08 / 

AE-Nr

. 8356

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Summary of Contents for EX-CSS 180

Page 1: ... applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual labelled with the caution or warning symbol above the country specific installation standards as well as all prevailing safety regulat...

Page 2: ... situation the diagnostic output will be switched off after approx 10 seconds The safety outputs are disabled when the fault is active for 1 minute Signal combination diagnostic output disabled and safety outputs still enabled can be used to shut down the machine in a controlled manner After fault rectification the error message is reset by opening and re closing the corresponding safety guard The...

Page 3: ... can be fixed using the supplied M18 nuts A F 24 The max tightening torque of the supplied screws is 500 Ncm Alternatively the H18 fixing clamp accessory can be used for the fixation of the safety sensor A concealed mounting is possible however this reduces the switching distance The reduction will be lower when the sensor protrudes a few mm The CST 180 1 actuator has two fixing holes displaced by...

Page 4: ...anent over voltage Under fault conditions the voltage must not exceed 60 V supply units according to IEC 60204 1 is recommended The safety outputs can be integrated into the safety circuit of the control system For applications of PL e control category 4 to ISO 13849 1 the safety outputs of the safety sensor or sensor of the chain must be wired to a safety monitoring module of the same control cat...

Page 5: ...ed is load dependent 300 mΩ at 1 A current load i e max load of the safety outputs is 2 x 500 mA 30 mΩ at 100 mA current load i e 2x 50 mA load when a safety monitoring module is connected Power consumption of a safety sensor approx 30 mA Diagnostic output of a safety sensor max 50 mA An approx 200 m long sensor chain with 6 sensors 0 5 mm cable section and at 20 C features approx 2 V voltage drop...

Page 6: ...sor can be readjusted before the safety outputs are disabled thus stopping the machine Errors in the coding of the actuator at the outputs of the sensor or in the sensor are signalled by the red LED After a short analysis of the active fault signalled by the red permanent signal the defined error is indicated by flash pulses The safety outputs are enabled in a delayed manner when the fault is acti...

Page 7: ...d the full quality assurance system referred to in Appendix IV 2014 34 EU TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n 0035 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal May 2 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original...

Page 8: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: