Operating instructions

Safety sensor

EX-CSS 180

EN

3.3  Switching distance

The graphs show the switch-on and switch-off points of the sensor 

due to the approach of the actuator. The maximum misalignment of 

the actuator with regard to the sensor centre is 7 mm. A concealed 

mounting of the sensor and the actuator will reduce the switching 

distance.

S

V

Key

S = switching distance 

V = axial misalignment

-5

-6

-7

-8

5 6 7 8

5

0

[mm]

0

-1

-2

-3

-4

1

2 3 4

8

10

S

S

ar

S

OFF

S

ON

S

ao

S [mm]

V [mm]

Typical response range of the EX-CSS 180 sensor

s

ON

 

switching point

s

off

 

switch-off point

S

h

 

hysteresis range

 s

= s

OFF

 – s

ON

S

ao

  

Assured switching distance

S

ar

  

Assured switch-off distance

3.4  Adjustment

The LED in the end cap of the safety sensor can be used as adjustment 

tool. The yellow flashing LED of a sensor signals if an adjustment of the 

switching distance is required. Reduce the distance between the sensor 

and the actuator, until the LED in the end cap of the safety sensor is 

continuously lit yellow. In this position, a reliable switching position 

of the sensor is obtained. (also refer to "Operating Principle of the 

Diagnostic Outputs").

The proper functionality must always be checked by means of the 

connected safety-monitoring module. 

4.  Rear side Electrical connection

4.1  General information for electrical connection

The electrical connection may only be carried out by 

authorised personnel in a de-energised condition.

The power supply for the safety sensors must provide protection 

against permanent over-voltage. Under fault conditions, the voltage 

must not exceed 60 V.  supply units according to IEC 60204-1 is 

recommended.

The safety outputs can be integrated into the safety circuit of the control 

system. For applications of PL e / control category 4 to ISO 13849-1, 

the safety outputs of the safety sensor or sensor of the chain must be 

wired to a safety monitoring module of the same control category .

Requirements for the connected safety-monitoring module:

•  Dual-channel safety input, suitable for p-type safety sensors with NC 

function.

The safety-monitoring module must tolerate internal functional tests of 

the sensors with cyclic switch-off of the sensor outputs for max. 2 ms. 

The safety-monitoring module must not be equipped with a cross-wire 

detection function. Short-circuit recognition by the evaluation is not 

necessary.

Information for the selection of suitable safety-monitoring 

modules can be found in the Schmersal catalogues or in the 

online catalogue on the Internet: www.schmersal.net.

4.2  Connection example

Sensor with safety inputs and safety outputs in one pre-wired cable: 

The series-wiring of multiple safety sensors is realised by wiring in the 

control cabinet or in on-site junction boxes.

Colour

Connection example

BN

(brown)

A1 Ue

BU

(blue)

A2 GND

VT

(violet)

X1 Safety input 1 

WH

(white)

X2 Safety input 2 

BK

(black)

Y1 Safety output 1 

RD

(red)

Y2 Safety output 2 

GY

(grey)

Diagnostic output

WH

VT

GY

BK

RD

BN

BU

4.3  Series wiring

A 200 m long sensor chain can be set up. Please note that voltage 

losses could occur (due to cable length, cable section, voltage drop/

sensor)! For longer cable lengths, the section of the connecting cables 

must be taken as large as possible.

Summary of Contents for EX-CSS 180

Page 1: ... applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual labelled with the caution or warning symbol above the country specific installation standards as well as all prevailing safety regulat...

Page 2: ... situation the diagnostic output will be switched off after approx 10 seconds The safety outputs are disabled when the fault is active for 1 minute Signal combination diagnostic output disabled and safety outputs still enabled can be used to shut down the machine in a controlled manner After fault rectification the error message is reset by opening and re closing the corresponding safety guard The...

Page 3: ... can be fixed using the supplied M18 nuts A F 24 The max tightening torque of the supplied screws is 500 Ncm Alternatively the H18 fixing clamp accessory can be used for the fixation of the safety sensor A concealed mounting is possible however this reduces the switching distance The reduction will be lower when the sensor protrudes a few mm The CST 180 1 actuator has two fixing holes displaced by...

Page 4: ...anent over voltage Under fault conditions the voltage must not exceed 60 V supply units according to IEC 60204 1 is recommended The safety outputs can be integrated into the safety circuit of the control system For applications of PL e control category 4 to ISO 13849 1 the safety outputs of the safety sensor or sensor of the chain must be wired to a safety monitoring module of the same control cat...

Page 5: ...ed is load dependent 300 mΩ at 1 A current load i e max load of the safety outputs is 2 x 500 mA 30 mΩ at 100 mA current load i e 2x 50 mA load when a safety monitoring module is connected Power consumption of a safety sensor approx 30 mA Diagnostic output of a safety sensor max 50 mA An approx 200 m long sensor chain with 6 sensors 0 5 mm cable section and at 20 C features approx 2 V voltage drop...

Page 6: ...sor can be readjusted before the safety outputs are disabled thus stopping the machine Errors in the coding of the actuator at the outputs of the sensor or in the sensor are signalled by the red LED After a short analysis of the active fault signalled by the red permanent signal the defined error is indicated by flash pulses The safety outputs are enabled in a delayed manner when the fault is acti...

Page 7: ...d the full quality assurance system referred to in Appendix IV 2014 34 EU TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n 0035 Person authorised for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal May 2 2017 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original...

Page 8: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Reviews: