Starting and operating instructions

Example of rating plate

 

Year of manufacture 

Type designation 

Main power 

Voltage/method of 

start 

Rated current 

Manufacturer, address

 

Degree of protection 

Speed of rotation 

Serial number 

Rated power 

Frequency 

Weight 

Max. flow

 

Delivery head

Applications

These  starting  and  operating  instructions  are  applicable  to  electric  submersible  pumps 

specified on the cover. The pumps are intended for pumping water that may contain abra-

sive particles.

c

DANGER! The pump must not be used in an explosive or flammable 

environments or for pumping flammable liquids.

The pumps conform to the EU machine directive. See rating plate.
The manufacturer guarantees that a new pump will not emit airborne noise in excess of 70 

dB(A) during normal operation, when either fully or partially submerged.

m

CAUTION! 
The pump must not be run if it has been partially dismantled.

c

CAUTION!  Earth  leakage  detector  (RCD  Residual-current  device)  is 

recommended to be used when a person come in contact with either 

the pump or the pumped media.

Special  regulations  apply  for  permanent  installation  of  pumps  in  swimming 

pools.

Product description

Limitations

Immersion depth: up to 20 m/65 ft (J 5: 8 m/26 ft). Liquid temperature: up to 40°C (105°F).

Motor

Single-phase AC motor or 3-phase squirrel-cage induction motor for 50 or 60 Hz.

Level control

Some pumps can be equipped with float switch for automatic level control.

Motor protection

Single-phase pumps have a built in start- and run-capacitor. For built in motor protection, 

the thermal contacts in the motor are fitted to disconnect the power at high temperature. 

The thermal contacts can as alternative be connected to an external motor protection.

Electric cable

HO7RN-F or equivalent cable. If the cable is longer than 20 m, the voltage drop must be 

taken into account. Note that the pumps can be supplied with different cables and for dif-

ferent connection methods. 

Handling

The pump can be transported and stored either vertically or horizontally. Make sure that it 

is secured and cannot roll.

m

CAUTION! The pump must always rest on a firm surface so that it will 

not overturn. This applies to all handling, transport, testing and in-

stallation.

m

CAUTION!  Always  lift  the  pump  by  the  lifting  handle  -  never  by  the 

motor cable or hose.

NOTE! Always protect the cable end so that no moisture will penetrate into the 

cable. Water could otherwise seep into the terminal compartment or into the mo-

tor through the cable.

If the pump is stored for a long period of time, protect it against dirt and heat.
After a longer period of storage, the pump must be inspected and the impeller must be 

rotated by hand before the pump is taken into operation. Check the seals and cable entry 

particularly carefully.

Installation

Safety measures

In order to reduce the risk of accidents during service and installation work, take extreme 

care and bear in mind the risk of electrical accidents.

m

CAUTION! The lifting tackle must always be designed to suit the pump 

weight. See under the heading ”Product description”.

Pump installation

Arrange the cable run so that the cables will not be kinked or nipped.
Connect the cable. Connect the delivery piping. Hoses, pipes and valves must be selected 

to suit the pump delivery head. 
Place the pump on a firm surface which will prevent it from overturning or burrowing down. 

The pump can also be suspended by the lifting handle slightly above the bottom.

Electrical connections

The pump must be connected to terminals or starting equipment installed at a level at which 

it cannot be flooded.

c

CAUTION! All electrical equipment must always be earthed (ground-

ed). This applies both to the pump and to any monitoring equipment.

c

CAUTION! The electrical installation must conform to national and lo-

cal regulations.

Check that the mains voltage, frequency, starting equipment and method of starting agree 

with the particulars stamped on the motor rating plate.
N.B. A pump designed for 400 volt can be used in the 380-415 volt range. A pump designed 

for 230 volt can be used in the 220-245 volt range.

Connection of stator and motor conductors

If  the  pump  is  not  fitted  with  a  connector,  connect  it  in  accordance  with  valid  wiring  

diagram. Wiring diagrams are included in the workshop manual.

Cable marking on pump cables:
L1, L2, L3 = phase marking at D.O.L start / U1, V1, W1, U2, V2, W2 = stator marking at star-

delta start / F0, F1, F3, F4 = thermal sensor marking / D1, D2 = leakage sensor marking, 

must be connected to external relay / GC = ground check marking

The electrical installation shall be inspected by an authorized electrician.

Operation

Before starting:

Check the direction of rotation of the pump (see fi-

gure).  At  the  instant  of  starting,  the  pump  will  jerk 

anti-clockwise when viewed from above.

If the direction of rotation is incorrect, transpose two 

phases. 

 

 

Starting 

jerk

m

CAUTION!  The starting jerk may be violent. Don’t hold the pump han-

dle when checking the direction of rotation. Make sure that the pump 

is firmly supported and cannot rotate.

c

CAUTION!  Reversal of the direction of rotation on a plug that has no 

phase transposing device may be done only by an authorized person.

m

CAUTION!  If the built-in motor protection has tripped, the pump will 

stop but will restart automatically when it has cooled down.

Service and maintenance

c

CAUTION!  Before any work is started, check that the pump is isolated 

from the power supply and cannot be energized.

Regular inspection and preventive maintenance will ensure more reliable operation. The 

pump should be inspected every six months, but more frequently if the operating condi-

tions are difficult.
For a complete overhaul of the pump, please get in touch with an authorized ABS workshop 

or your ABS dealer.

m

CAUTION!  
If a cable is damaged, it must always be replaced.

m

CAUTION!  A worn impeller often has sharp edges. Take care not to 

cut yourself on them.

m

CAUTION!  In the event of inward leakage, the oil housing may be pres-

surized. When removing the oil plug, hold a piece of cloth over it to 

prevent oil from splashing.

m

CAUTION!  J 205 - 604
Two overhead cranes must be used to lay the pump or motor section 

on its side safely. When the pump or motor section has been laid on 

its side, always secure it with wedges from both sides to prevent it 

from rolling away.

 

End-of-life units can be returned to ABS or recycled in accordance with 

local regulations.

The manufacturer reserves the right to change  the design and specifications.

GB

Summary of Contents for J Series

Page 1: ...es de arranque e opera o 9 K ivitus ja kasutusjuhised 10 Start og driftsinstruktioner 11 K ynnistys ja k ytt ohje 12 13 Start en bedrijfstellingsaanwijzingen 14 Start og driftsveiledning 15 16 Pokyny...

Page 2: ...54 50 60 Hz J 84 50 60 Hz J 205 50 60 Hz J 405 50 60 Hz J 604 50 60 Hz ABS submersible drainage pump JC JC 24 50 60 Hz JC 44 50 60 Hz JC 34 50 60 Hz JC 54 50 60 Hz JC 84 50 60 Hz ABS submersible slud...

Page 3: ...abeln Anslut tryckledningen Slangar r r och ventiler m ste dimensioneras efter pumpens tryckh jd St ll pumpen p ett fast underlag som hindrar att den v lter eller gr ver ner sig Pumpen kan ven h ngas...

Page 4: ...kinked or nipped Connect the cable Connect the delivery piping Hoses pipes and valves must be selected to suit the pump delivery head Place the pump on a firm surface which will prevent it from overt...

Page 5: ...nicht geknickt oder eingeklemmt werden Kabel anschlie en Druckleitung anschlie en Schl uche Rohre und Ventile m ssen ent sprechend der Pumpenf rderh he dimensioniert sein Pumpe auf eine feste Standfl...

Page 6: ...oient pinc s en aucun point de leur trajet Brancher le c ble Raccorder la canalisation de refoulement Les flexibles les conduits et les vannes doivent tre calcul s en fonction de la hauteur de refoule...

Page 7: ...eve essere tale da non presen tare piegature o schiacciamenti Collegare il cavo Collegare il tubo di mandata I tubi e le valvole devono essere dimen sionati alla portanza della pompa Posizionare la po...

Page 8: ...a Instalaci n de la bomba Disponer el tendido de los cables de manera que no queden pillados ni retorcidos Conectar el cable Conectar la tuber a de descarga La selecci n de mangueras tuber as y v lvul...

Page 9: ...idos Ligue o cabo Ligue o condutor de press o A dimens o de tubos canos e v lvulas deve estar de acordo com a press o m xima da bomba Coloque a bomba numa base firme que a impe a de tombar ou de se en...

Page 10: ...gelt ning selles poleks murdekohti hendage juhtmed hendage pumba voolikud Voolikud torud kraanid ja ventiilid peavad olema vastavuses pumba t stek rgusega Asetage pump tasasele pinnale nii v ldite sel...

Page 11: ...n k eller bliver klemt Tilslut elkablet Tilslut trykslangen Slanger r r og ventiler skal dimensio ne res efter pumpens trykh jde Stil pumpen p et stabilt underlag der hindrer at pumpen v lter eller gr...

Page 12: ...en mukaan Aseta pumppu kiinte lle alustalle siten ettei pumppu voi kaatua tai vajota Pumppu voi daan my s ripustaa nostokahvastaan jonkin verran pohjan yl puolelle S hk kytkent Pumppu on liitett v s h...

Page 13: ...70 dB A m c RCD 20 m J 5 8 m 40 C 50 60 Hz HO7RN F 20 m m m c c 400 volt 380 415 volt 230 volt 220 245 volt L1 L2 L3 D O L U1 V1 W1 U2 V2 W2 F0 F1 F3 F4 D1 D2 GC m c m c ABS ABS m m m m J 205 604 ABS...

Page 14: ...el aan Sluit de drukleiding aan Slangen buizen en kleppen moe ten worden gedimensioneerd op de drukhoogte van de pomp Plaats de pomp op een solideondergrond zodat hij niet omver kan vallen of zich in...

Page 15: ...opl til kabelen Kopl til trykkledningen Slanger r r og ventiler m dimensjoneres etter pumpens trykkh yde Sett pumpen p et stabilt underlag som hindrer at den velter eller graver seg ned Pumpen kan ogs...

Page 16: ...16 c 70 dB A m c RCD 20 65 J 5 8 m 26 40 C 105 F 50 60 Hz T HO7RN F 20 m m m c c N B 400 380 415 230 220 245 L1 L2 L3 D O L U1 V1 W1 U2 V2 W2 F0 F1 F3 F4 D1 D2 GC m c m c ABS m m m m J 205 604 ABS BG...

Page 17: ...la Upravte kabelovou trasu tak aby nedoch zelo k zauzlen a p isk pnut kabel Zapojte kabel Zapojte p vodn potrub Zvolte takov hadice trubky a ventily kter odpo v daj v tla n v ce Um st te erpadlo na pe...

Page 18: ...u Cijevi crijeva i ventili se moraju odabrati tako da odgovaraju visini dobave pumpe Pumpu postavite na tvrdu povr inu koja e sprije iti prevrtanje ili propadanje Pumpa se tako er mo e ovjesiti putem...

Page 19: ...sse be a vezet ket Csatlakoztassa az elvezet cs vet A t ml ket csatlakoz kat s szelepeket a szivatty emel si magass g nak megfelel en kell megv lasztani Helyezze a szivatty t biztos fel letre amely m...

Page 20: ...pausti Prijunkite kabel Prijunkite tiekimo vamzd arnos vamzd iai ir vo tuvai turi b ti parinkti tokie kad tikt siurblio tiekimo galvutei Pad kite siurbl ant tvirto pavir iaus kad siurblys nenuvirst ar...

Page 21: ...kabe i neb tu saviju ies vai saloc ju ies Pievienojiet kabeli Pievienojiet pieg des cauru vadus tenes caurules un v rstus ir j izv las t lai tie b tu piem roti s k a pieg des galvi ai Novietojiet s k...

Page 22: ...wa y do ci nienia pracy pompy Umie pomp na takiej powierzchni kt ra uchroni j przed wywr ceniem lub zapada niem Pompa r wnie mo e zosta zawieszona na r czce do jej podnoszenia lekko ponad dnem zbiorni...

Page 23: ...aseul cablului astfel nc t cablul s nu fie r sucit sau presat Conecta i cablul Conecta i conductele de refulare Furtunurile tuburile i supapele trebuie alese pentru a se potrivi cu n l imea de refular...

Page 24: ...cevi ter ventile izberite ustrezno glede na odvodno razdaljo rpalke rpalko postavite na trdno podlago kar bo prepre ilo prevra anje ali vdiranje v tla rpalka lahko tudi visi nizko nad tlemi obe ena na...

Page 25: ...ov trasu tak aby sa k ble nemohli zauzli a pri tipn Zapojte k bel Zapojte pr vodn potrubie Zvo te tak hadice r ry a ventily ktor odpove daj pr vodnej pr rube Umiestnite erpadlo na pevn povrch ktor zab...

Page 26: ...k kafas na uygun ekilde se ilmelidir Pompay devrilmesine veya durdu u zemini oymas na engel olacak sa lam bir y zeye yerle tirin Pompa kald rma kolu vas tas yla zeminin biraz zerinde ask ya da al nabi...

Page 27: ...Oc e c 70 A m c RCD 20 65 J 5 8 m 26 40 C 105 F 3 50 60 HO7RN F 20 m m m c c NB 400 380 415 230 220 245 L1 L2 L3 DOL U1 V1 W1 U2 V2 W2 Y D F0 F1 F3 F4 D1 D2 GC m c m c ABS ABS m m m m J 205 604 ABS R...

Page 28: ...28 c EU 70 A m c RCD 20 65 J 5 8 26 40 C 105 F AC 50 60 Hz 3 HO7RN F 20 m m m c c 400 380 415 230 220 245 L1 L2 L3 U1 V1 W1 U2 V2 W2 F0 F1 F3 F4 D1 D2 GC m c m c ABS ABS m m m m J 205 604 ABS CN...

Page 29: ...29...

Page 30: ...30...

Page 31: ...kument To which this declaration relates is in conformity with the following standards or other normative documents Auf das sich diese Erkl rung bezieht mit den folgenden Normen oder normativen Dokume...

Page 32: ...ABS Production sgatan 3 SE 914 32 Nordmaling Sweden Phone 46 0 10 47 47 230 Fax 46 0 930 39 519 info absgroup com www absgroup com Copyright 2009 ABS...

Reviews: