TPU2000/2000R Modbus/Modbus Plus Automation Guide
323
0
not used reserved for fixed DIFF TRIP
1
Contact OUT5
2
Contact OUT7
3
Contact OUT4
4
Contact OUT6
5
Contact OUT3
6
Contact OUT2
7
Contact OUT1
8
spare
9
spare
10
spare
11
spare
12
spare
13
spare
14
spare
15
spare
11.7 Receive Programmable Output User Defined Names (3 11 7)
User definable 8 char output strings. Byte 9 is an implied NULL.
Msg byte Definition
1/1
Most significant high byte of password
1/2
Most significant low byte of password
1/3
Least significant high byte of password
2/1
Least significant low byte of password
2/2
spare
2/3
C Subcommand = 0xb7
3/1-5/2
OUT1 Character String 8 bytes
5/3-8/1
OUT2 Character String 8 bytes
8/2-10/3
OUT3 Character String 8 bytes
11/1-13/2
OUT4 Character String 8 bytes
13/3-16/1
OUT5 Character String 8 bytes
16/2-18/3
OUT6 Character String 8 bytes
19/1-21/2
OUT7 Character String 8 bytes
21/3-24/1
spare Character String 8 bytes
24/2-26/3
spare Character String 8 bytes
27/1-29/2
spare Character String 8 bytes
29/3-32/1
spare Character String 8 bytes
32/2-34/3
spare Character String 8 bytes
35/1-37/2
spare Character String 8 bytes
37/3-40/1
spare Character String 8 bytes
40/2
Checksum
high
byte
40/3
Checksum low byte
11.8,9,10 Receive Relay Settings ( 3 11 X )
( 3 11 8 ) = Primary Settings
( 3 11 9 ) = Alternate 1 Settings
( 3 11 10 ) = Alternate 2 Settings
Low byte consists of bits 0 through 7.
High byte consists of bits 8 through 15.
Curve Selection Type I
0 = Extremely Inverse
1 = Very Inverse
2 = Inverse
3 = Short Time Inverse
4 = Definite Time
Summary of Contents for TPU2000
Page 10: ......