TPU2000/2000R Modbus/Modbus Plus Automation Guide
161
Register Item
Description
Bit 6 = 150P-1
Bit 7 = 150N-1
Bit 8 = 46-1
Bit 9 = 51P-2
Bit10 = 51G (3 Winding)
51G-2 (2 Winding)
Bit 11 = 50P-2
Bit 12 = 50G (3 Winding)
50G-2 (2 Winding)
Bit 13 = 150P-2
Bit 14 = 150G (3 Winding)
150N-2 (2 Winding)
Bit 15 = 46-2 (msb)
2
nd
Winding 1 Phase Instantaneous Overcurrent Control
2
nd
Winding 1 Neutral Instantaneous Overcurrent Control
Winding 1 Negative Sequence Control
Winding 2 Phase Instantaneous Overcurrent Control
Ground Time Overcurrent Control
Winding 2 Ground Time Overcurrent Control
Winding 2 Phase Instantaneous Overcurrent Control
1
st
Ground Time Overcurrent Control
1
st
Winding 2 Ground Time Overcurrent Control
2
nd
Winding 2 Phase Time Overcurrent Control
2
nd
Ground Instantaneous Control
2
nd
Winding 2 Neutral Phase Instantaneous Control
Winding 2 Negative Sequence Control
63980
Bit 0 = Thru Fault (lsb)
Bit 1 = Harmonic Restraint
Bit 2 = External Input
Bit 3 = 51P-3 (3 Winding Only)
Bit 4 = 51N-3 (3 Winding Only)
Bit 5 = 50P-3 (3 Winding Only)
Bit 6 = 50N-3 (3 Winding Only)
Bit 7 = 150P-3 (3 Winding Only)
Bit 8 = 150N-3 (3 Winding Only)
Bit 9 = 46-3 (3 Winding Only)
Bit 10 = 51N-2 (3 Winding Only)
Bit 11 = 50N-2 (3 Winding Only)
Bit 12 = 150N-2 (3 Winding
Only)
Bit 13 = Reserved
Bit 14 = Reserved
Bit 15 = Reserved (msb)
Through Fault Control
Harmonic Restraint Control
External Input Control
Winding 3 Phase Time Overcurrent Control
Winding 3 Neutral Time Overcurrent Control
1
st
Winding 3 Phase Instantaneous Overcurrent Control
1
st
Winding 3 Neutral Inst. Overcurrent Control
2
nd
Winding 3 Phase Instantaneous Overcurrent Control
2
nd
Winding 3 Neutral Instantaneous Overcurrent Control
Winding 3 Negative Sequence Control
Winding 3 Neutral Time Overcurrent Control
1
st
Winding 3 Neutral Inst. Overcurrent Control
2
nd
Winding 3 Neutral Inst. Overcurrent Control
63084 Reserved
Reserved
63085-
63199
Reserved Reserved
OSCILLOGRAPHICS 6X DATA RETRIEVAL MAP
TPU REGISTER MAP MEMORY
Data Control Register
Oscillographic
Configuration
Settings
63968
63969
63199
EC
INTERNAL
TPU MEMORY
Non-Volatile
Send Value “2” to
Control Register 63968
Send Password to Registers
63969 and 63970
Not Viewable
By Operator
Viewable
Via Modbus/Modbus Plus
OSCILLOGRAPHICS 6X STORAGE MAP
TPU REGISTER MAP MEMORY
Data Control Register
Oscillographic
Configuration
Settings
63968
63969
63199
..
EC
INTERNAL
TPU MEMORY
Non-Volatile
Send “Data” to
Registers 63972 -63199
(Oscillographic Configuration)
Not Viewable
By Operator
Viewable
Via Modbus/Modbus Plus
Reset to 0.
Send a Value of 1 to Relay to
Save Configuration Data. Send Password to
Registers 63969 and 63970
Write a 0
to Control
Register
Figure 5-60. Oscillographics Retrieval/Storage Parameterization Philosophy