7.6.7
Operation principle
Negative sequence based overcurrent function (DNSPTOC, 46) has two settable
current levels, setting parameters
PickupCurr_OC1
and
PickupCurr_OC2
. Both
features have definite time characteristics with settings
tDef_OC1
and
tDef_OC2
respectively. It is possible to change the direction of these steps to
forward
,
reverse
or
non-directional
by setting parameters
DirMode_OC1
and
DirMode_OC2
. At too low
polarizing voltage the overcurrent feature can be either blocked or non-directional.
This is controlled by settings
ActLowVolt1_VM
and
ActLowVolt2_VM
.
7.6.8
Technical data
Table 64:
DNSPTOC (46) Technical data
Function
Range or value
Accuracy
Operate current
(2.0 - 5000.0) % of
IBase
± 1.0% of I
r
at I <I
n
± 1.0% of I at I > I
n
Reset ratio
> 95 %
-
Low voltage level for memory
(0.0 - 5.0) % of
VBase
< ± 0.5% of V
n
Relay characteristic angle
(-180 - 180) degrees
± 2.0 degrees
Relay operate angle
(1 - 90) degrees
± 2.0 degrees
Timers
(0.00 - 6000.00) s
± 0.5% ± 25 ms
Operate time, non-directional
30 ms typically at 0 to 2 x I
set
20 ms typically at 0 to 10 x I
set
-
Reset time, non-directional
40 ms typically at 2 to 0 x I
set
-
Operate time, directional
30 ms typically at 0 to 2 x I
set
20 ms typically at 0 to 10 x I
set
-
Reset time, directional
40 ms typically at 2 to 0 x I
set
-
Critical impulse time
10 ms typically at 0 to 2 x I
set
2 ms typically at 0 to 10 x I
set
-
Impulse margin time
15 ms typically
-
Dynamic overreach
< 10% at t = 300 ms
-
1MRK 505 277-UUS C
Section 7
Current protection
121
Technical Manual
Summary of Contents for REB650
Page 1: ...Relion 650 series Busbar protection REB650 ANSI Technical Manual ...
Page 2: ......
Page 34: ...28 ...
Page 52: ...46 ...
Page 128: ...122 ...
Page 150: ...144 ...
Page 192: ...186 ...
Page 222: ...216 ...
Page 360: ...354 ...
Page 378: ...372 ...
Page 437: ...IEC12000585 V1 EN 1MRK 505 277 UUS C Section 16 IED physical connections 431 Technical Manual ...
Page 438: ...IEC12000586 V1 EN Section 16 1MRK 505 277 UUS C IED physical connections 432 Technical Manual ...
Page 439: ...IEC12000587 V1 EN 1MRK 505 277 UUS C Section 16 IED physical connections 433 Technical Manual ...
Page 440: ...IEC12000588 V1 EN Section 16 1MRK 505 277 UUS C IED physical connections 434 Technical Manual ...
Page 441: ...IEC12000589 V1 EN 1MRK 505 277 UUS C Section 16 IED physical connections 435 Technical Manual ...
Page 442: ...IEC12000590 V1 EN Section 16 1MRK 505 277 UUS C IED physical connections 436 Technical Manual ...
Page 443: ...IEC12000591 V1 EN 1MRK 505 277 UUS C Section 16 IED physical connections 437 Technical Manual ...
Page 444: ...IEC12000592 V1 EN Section 16 1MRK 505 277 UUS C IED physical connections 438 Technical Manual ...
Page 454: ...448 ...
Page 503: ...497 ...