The digital inputs comply with the requirements of current sinking inputs type 1
for rated voltage 24 VDC according to IEC 61131-2:2017 clause 6.4.4.2.
Note
If external power supplies are used, they must have over-current protection. A
recommendation is to have separate fuses (0.5A) for each channel (Ch1, Ch2)
to increase diagnostic coverage on inputs.
Note
If separate power supplies are used for each channel (Ch1, Ch2) they must have
common ground.
For more connections other than those illustrated above, carefully assess the risk
before use and contact your local ABB for support.
Connector X15
Description
Connector for Safety IO signals
Connection
S2L 3.50 90F
Type
Weidmüller
1728690000
Article number
2
4
6
1
3
5
8
10
12
7
9
11
14
16
13
15
18
17
xx1800000555
Name
Pin
Name
Pin
24V_MON
2
MON_PB1
1
24V_MON
4
MON_LAMP1
3
-
6
-
5
24V_CH2_EXT
8
0V_IO_EXT
7
AS_CH2_P
10
AS_CH2_N
9
ESOUT2_P
12
ESOUT2_N
11
ESOUT1_P
14
ESOUT1_N
13
AS_CH1_P
16
AS_CH1_N
15
24V_CH1_EXT
18
0V_IO_EXT
17
The connector X15 allows for connecting
automatic stop
devices.
Automatic Stop
is only operational in automatic mode. See
More information is also available in
Application manual - Functional safety and
SafeMove
.
Continues on next page
Product manual - OmniCore V400XT
99
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.9 Descriptions for connectors
Continued
Summary of Contents for OmniCore V400XT
Page 1: ...ROBOTICS Product manual OmniCore V400XT...
Page 180: ...This page is intentionally left blank...
Page 338: ...This page is intentionally left blank...
Page 342: ...This page is intentionally left blank...
Page 428: ...This page is intentionally left blank...
Page 460: ...This page is intentionally left blank...
Page 464: ......
Page 465: ......