4 Maintenance
4.1 Maintenance schedule for the OmniCore controller
General
The controller must be maintained at regular intervals to ensure its function. The
activities and intervals are described in this section.
Activities and intervals
Detailed in section:
Interval
Maintenance
activity
Equipment
Inspecting the OmniCore V400XT
controller on page 160
12 months
i
Inspection
Complete controller
Cleaning air filter on page 161
Cleaning
Air filter
Replacement of air filter on page 167
24 months
Replacement
Air filter
Inspecting the OmniCore V400XT
controller on page 160
6 months
Inspection
System fans
Cleaning of the controller cabinet
on page 164
Cleaning
Control cabinet
Cleaning the FlexPendant on
page 165
When needed
Cleaning
FlexPendant
Function test of emergency stop on
page 171
12 months
Function test
Emergency stop
(FlexPendant)
Function test of manual, auto, and
manual full speed mode with Flex-
Pendant on page 172
12 months
Function test
Manual, auto and
manual full speed
mode with FlexPend-
ant
Function test of three-position en-
abling device on page 173
12 months
Function test
Enabling device
Function test of Automatic Stop on
page 175
12 months
Function test
Auto stop (tested if
used)
Function test of General Stop on
page 176
12 months
Function test
General stop (tested
if used)
Function test of external emergency
stop on page 177
12 months
Function test
External emergency
stop (tested if used)
Function test of ESTOP_STATUS
output on page 178
12 months
Function test
ESTOP_STATUS
output (tested if
used)
Function test of reduced speed
control on page 179
.
During commis-
sioning
Function test
Reduced speed
control
i
The interval depends on the working environment of the equipment: a cleaner environment may
extend the maintenance interval and vice versa.
Function test after replacement of component
After replacing a component in the controller, the function tests should be
performed. See
Product manual - OmniCore V400XT
159
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
4 Maintenance
4.1 Maintenance schedule for the OmniCore controller
Summary of Contents for OmniCore V400XT
Page 1: ...ROBOTICS Product manual OmniCore V400XT...
Page 180: ...This page is intentionally left blank...
Page 338: ...This page is intentionally left blank...
Page 342: ...This page is intentionally left blank...
Page 428: ...This page is intentionally left blank...
Page 460: ...This page is intentionally left blank...
Page 464: ......
Page 465: ......