Note/Illustration
Action
xx2300001492
Remove the screws and pull the power
unit out from the two guiding pins on the
mounting plate.
CAUTION
Only the sheet metal on the power unit
can be used for holding.
Do not touch the connectors or the filter
on the power unit.
2
Refitting the power unit
Refitting the power unit
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
xx2300001842