Safety board front panel connectors
xx2300000501
CAUTION
Safety functions must be verified before use. Safety functions must be tested
regularly.
Connector X13
Description
Connector for HMI signals
Connection
Dynamic D-2100D
Type
Tyco Electronics
1376137-1
Article number
Name
Pin
Name
Pin
ENABLE_CH1
B1
24V_CH1_HMI
A1
0V_IO_HMI
B2
HMI_ESTOP_CH1
A2
ENABLE_CH2
B3
HMI_ESTOP_CH2
A3
24V_CH2_HMI
B4
0V_IO_HMI
A4
0V_TPU
B5
24V_TPU
A5
24V_MON
B6
MON_LAMP
A6
24V_MON
B7
MON_PB
A7
-
B8
-
A8
-
B9
-
A9
-
B10
-
A10
Connector X14
Description
Connector for Safety IO signals
Connection
S2L 3.50 90F
Type
Weidmüller
1728680000
Article number
The connector X14 allows for connecting
general stop
and
emergency stop
devices.
General Stop
is operational in both manual mode and automatic mode. See
Protective stop and emergency stop on page 21
Continues on next page
Product manual - OmniCore V400XT
95
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.9 Descriptions for connectors