Note/Illustration
Action
xx2200001973
Insert the antenna cable through the
cable grommet.
3
Apply cable ties and suitable cable pro-
tection to ensure that the cable may not
be damaged by the door.
4
xx2300000672
Connect the antenna cable to the Connec-
ted Services gateway by rotating the
connector.
5
Concluding procedure
Note/Illustration
Action
.
Close the door.
1
Perform the function tests to verify that
the safety features work properly, see
2
222
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.2.5 Replacing the 4G Connected Services gateway
Continued