Note
Action
Screws: Hex socket head cap
screw M4x20 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Refit the screws and washers to the secure the
ball screw flange to the outer arm.
Tip
Pre-tighten the screws at 0.5Nm and slide the ball
screw up and down for five times. Then tighten
the screws at 3.8Nm to secure it.
3
Washers: Spring washer 9x4.3x1
Steel (4 pcs)
Tightening torque: 3.5 Nm ±10%
xx2100001082
Refitting the mechanical stopper
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free. See
Cut the paint or surface on the robot
before replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
Continues on next page
Product manual - IRB 920
515
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the ball screw
Continued
Summary of Contents for IRB 920
Page 1: ...ROBOTICS Product manual IRB 920 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 984: ...This page is intentionally left blank ...
Page 1000: ...This page is intentionally left blank ...
Page 1002: ...This page is intentionally left blank ...
Page 1006: ......
Page 1007: ......