
Note
Action
xx2100000949
Reconnect the connectors.
•
R2.MP1
•
R2.FB1
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
Route the cabling behind the axis-1 motor.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
4
Reconnecting the grounding cable connectors
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free. See
Cut the paint or surface on the robot
before replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
Screws: Hex socket head cap
screw M3x5 12.9 Lafre 2C2B/FC6.9
(3 pcs)
Secure the three grounding cables to the bracket
with the screw.
2
Tightening torque: 1.5 Nm ±10%
xx2100000947
Continues on next page
240
Product manual - IRB 920
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Summary of Contents for IRB 920
Page 1: ...ROBOTICS Product manual IRB 920 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 984: ...This page is intentionally left blank ...
Page 1000: ...This page is intentionally left blank ...
Page 1002: ...This page is intentionally left blank ...
Page 1006: ......
Page 1007: ......