Note
Action
For robots with protection class
IP30 (option 3350-300)
xx2100000943
Remove the screws.
3
Remove the cover.
Note
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Remove the cover and check the gasket.
Tip
Replace the gasket if needed.
4
For robots with protection class
IP54 (option 3350-540)
For robots with protection type
Clean Room (option 3351-1)
xx2100002451
Removing the SMB cover
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 49
2
Continues on next page
Product manual - IRB 920
135
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the main harness
Continued