Note
Action
Screws: Hexagon socket set
screws with flat point, ISO 4026
stainless steel M3x8 (2 pcs)
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
5
Tightening torque: 0.4 Nm ±10%
xx2100002398
Refit the locking screws.
Concluding procedure
Note
Action
For robots with protection type Clean Room:
1
Seal and paint the joints that have been opened.
See
Cut the paint or surface on the robot before
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
DANGER
Make sure all safety requirements are met when
performing the first test run.
2
Removing the lower mechanical stopper
Use these procedures to remove the lower mechanical stopper.
Preparations before removing the lower mechanical stopper
Note
Action
Decide which calibration routine to use, and take
actions accordingly prior to beginning the repair
procedure.
1
Move the ball screw to lower position.
2
Continues on next page
Product manual - IRB 920
409
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the mechanical stopper
Continued
Summary of Contents for IRB 920
Page 1: ...ROBOTICS Product manual IRB 920 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 984: ...This page is intentionally left blank ...
Page 1000: ...This page is intentionally left blank ...
Page 1002: ...This page is intentionally left blank ...
Page 1006: ......
Page 1007: ......