Note
Action
xx2100002398
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Loose the locking screws.
3
xx2100002399
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Remove the top cover from the ball screw.
4
xx2100002401
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Remove the screws on the flange with bearing.
5
xx2100002402
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Remove the flange with bearing.
6
Continues on next page
Product manual - IRB 920
493
3HAC075721-001 Revision: C
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the ball screw
Continued