Endura AZ30 series integral probe and remote transmitter
Combustion oxygen monitor
13 Transmitter Specification
104
COI/AZ30E–EN Rev. D
13 Transmitter Specification
Hazardous Area Certifications
Transmitter
Remote Terminal Housing
Transmitter Enclosures
Remote transmitter (mounted to remote terminal housing):
Wall-, pipe- or stand-mounted (mounting bracket supplied)
Integral transmitter:
Head-mounted to probe
Physical
Remote transmitter:
Aluminium (EN AC44200 or 47000)
Remote terminal housing:
316L stainless steel
Integral transmitter:
Aluminium transmitter housing / stainless steel probe and terminal housing
II 2 GD
Ex d IIB +H2 Gb (Ta –20 to 55 °C)
Ex tb IIIC T 85 °C Db IP66 (Ta –20 to 55 °C) IP66
Certified Component
IECEx BAS12.0050U
Baseefa12ATEX0078U
Class I Division 1 Groups BCD T6
Class I Zone 1 AEx/Ex d IIB+H2 T6
Class II Division 1 Groups EFG T6 (Ta –20 to 55 °C) Type 4X
FM Certificate No. 3039243
Max Current 1.2 A
II 2 GD
Ex d IIB +H
2
T6 Gb ( Ta –20 to 70 °C)
Ex tb IIIC T85°C Db (Ta –20 to 70 °C) IP66
Cert. No IECEx BAS12.0049X
Atex Cert No. Baseefa12ATEX0077X
Class I Division 1 Groups BCD T6
Class I Zone 1 AEx/Ex d IIB+H2 T6
Class II Division 1 Groups EFG T6 (Ta –20 to 55 °C) Type 4X
FM Certificate No. 3039243