background image

V

V

ip 396 485

ip 396 485

V

V

ip 396 4-20mA 485

ip 396 4-20mA 485

Energy Demand Meter

Energy Demand Meter

ADDITION TO THE USER MANUAL

ADDITION TO THE USER MANUAL

3YYYB087  Vip 396 Options Eng   rev 11/05

Via Vizzano 44 - 40044  Pontecchio Marconi (Bologna)Italy

Tel. +39 051 6782006 - Fax +39 051 845544

http://www.elcontrol-energy.net -

e-mail: Italia [email protected]

           estero: [email protected]

WARNING

 – 

Elcontrol Energy Net S.p.a.

 declines all liability for any damage to people or property caused by unsuitable or incorrect use of

its products. Elcontrol Energy Net  reserves the right to change product specifications without prior notice.

ENGLISH

Summary of Contents for Vip 396 485

Page 1: ...tecchio Marconi Bologna Italy Tel 39 051 6782006 Fax 39 051 845544 http www elcontrol energy net e mail Italia vendite elcontrol energy net estero sales elcontrol energy net WARNING Elcontrol Energy Net S p a declines all liability for any damage to people or property caused by unsuitable or incorrect use of its products Elcontrol Energy Net reserves the right to change product specifications with...

Page 2: ...U L T I P A N E L M E T E R kVA 3Ø SEL SET SINGLE PHASE THREE PHASE PAG M U L T I P A N E L M E T E R SEL SET SINGLE PHASE THREE PHASE PAG M U L T I P A N E L M E T E R kW 3Ø SEL SET SINGLE PHASE THREE PHASE PAG M U L T I P A N E L M E T E R kW 3Ø SEL SET SINGLE PHASE THREE PHASE PAG M U L T I P A N E L M E T E R 3Ø kVA Fig 3 VIP396 4 20mA 485 Fig 4 VIP396 4 20mA 485 Fig 5 VIP396 4 20mA 485 Fig 6 ...

Page 3: ...E PAG M U L T I P A N E L M E T E R SEL SET SINGLE PHASE THREE PHASE PAG M U L T I P A N E L M E T E R kW SEL SET SINGLE PHASE THREE PHASE PAG M U L T I P A N E L M E T E R kW SEL SET SINGLE PHASE THREE PHASE PAG M U L T I P A N E L M E T E R KVA SEL SET SINGLE PHASE THREE PHASE PAG M U L T I P A N E L M E T E R KVA SEL SET SINGLE PHASE THREE PHASE PAG M U L T I P A N E L M E T E R SEL SET SINGLE ...

Page 4: ...odel measurement page model VIP396 485 4 20mA set up page model VIP396 4 20mA 485 relay set up page model VIP396 ALM 485 VIP396 4 20mA 485 Fig 3 VIP396 4 20mA 485 By pressing the SET key the type of output either 4 20mA or 0 20mA can be selected Pressing the PAG key enables to go to the measure selection page corresponding to output 1 Fig 4 VIP396 4 20mA 485 Output 1 measure selection By pressing ...

Page 5: ...the SEL key enables to select the digit to modify or the measure to associate with the output 2 same as for output 1 E g 1 pulse 0 01 kVAh Pressing the SET key enables to modify the selected measure or digit Pressing the PAG key enables to return to the measurement page Fig 10 VIP 396 ALM 485 Relay output 1 set up Pressing the SET key enables to select one of the following measures and to associat...

Page 6: ...modify Pressing the SET key enables to modify the selected digit E g Hysteresis 02 Pressing the PAG key enables to go to the relay 1 operation delay time set up page Fig 14 VIP 396 ALM 485 Relay 1 operation delay time set up A delay figure between 000 and 999 can be set in the 3 bottom digits expressed in seconds Pressing the SEL key enables to select the digit to modify Pressing the SET key enabl...

Page 7: ... update time is 1 second RELAY OUTPUTS Max load 250 VAC rms 100mA rms 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 A B RS485 OUT1 OUT2 4 20mA VIP 396 4 20mA 485 1 2 3 4 5 6 OUT OUT OUT OUT A B RS485 1A 1B 2A 2B VIP 396 ALM 485 Fig 18 VIP 396 ALM 485 Output 2 hysteresis set up Same set up as in output 1 E g Hysteresis 34 Pressing the PAG key enables to go to the relay 2 operation delay time set ...

Reviews: