IM 11G06A01-02EN
2-6
2. SPECIFICATIONS
1st Edition : Oct. 27, 2023-00
2.2
Model and Suffix Code
IR800G
Model
Suffix code
Option
code
Specification
IR800G
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Rack Type Infrared Gas Analyzer
Type
-AJ
-AB
-AD
- - - - - - -
- - - - - - -
- - - - - - -
General (Japan)
General (CE, UKCA, RCM, GB)
General (CSA)
Measuring
Components
-A1
-A2
-A3
-A4
-A5
-B1
-B2
-B4
-B5
-B6
-C1
-C4
-D1
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
NO
SO
2
CO
CO
2
CH
4
NO+SO
2
NO+CO
CO+CO
2
CO+CH
4
CO
2
+CH
4
NO+SO
2
+CO
CO+CO
2
+CH
4
NO+SO
2
+CO+CO
2
O
2
Analyzer
-N
-1
-2
-3
-4
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
- - - - - - -
None
ZR22G (*1)
4-20mA input (*1)
Built-in paramagnetic O
2
Built-in paramagnetic O
2
(H
2
background) (*2)
NO Measuring Range
- □□
- - - - - - -
SO
2
Measuring Range
- □□
- - - - - - -
CO Measuring Range
- □□
- - - - - - -
CO
2
Measuring Range
- □□
- - - - - - -
CH
4
Measuring Range
- □□
- - - - - - -
O
2
Measuring Range
- □□
- - - - - - -
Digital Communication
-N
-R
- - - - - - -
- - - - - - -
None
RS-485
Automatic Validation
-N
-V
- - - - - - -
- - - - - - -
None
Automatic Validation
Gas connection
-R
-T
- - - - - - -
- - - - - - -
Rc1/4
1/4NPT
Display Language
-J
-E
-C
- - - - - - -
- - - - - - -
- - - - - - -
Japanese
English
Chinese
Mount Type
-S
-R
- - - - - - -
- - - - - - -
Rack with slide rail
Rack without slide rail
—
-NN
- - - - - - -
Always "-NN"
—
-NN
- - - - - - -
Always "-NN"
/U
Unit change (mg/m
3
, g/m
3
) (*3)
/P
Air purging inlet
/A
Peak alarm (*4)
/K
O
2
compensation (*5)
/NX
Display NOx instead of NO
/PR
Pressure Regulator (For Sample/
Reference gas line, Pair) (*6)
(*1) Oxygen analyzer is not included. Please arrange it separately
(*2) If the sample gas contains more than 100 ppm hydrogen, select the "-4" specification for H2 background.
(*3) Select this option when one or more of NO, SO
2
, or CO is included in the measuring component.
(*4) Available when CO is included in the measuring component
(*5) Available when the O
2
analyzer specification is other than "-N" and one or more of NO, SO
2
, or CO is included in the
measuring component.
(*6) One pressure regulator valve for the sample gas and one for the reference gas are included. Select this option if input
pressure is not stable.
Содержание IR800G