App-4
IM DL850-03EN
(Continued from previous page)
Record Length
2.5 Mpoint
5 Mpoint
10 Mpoint
25 Mpoint
50 Mpoint
Time/div Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
6 h
10
2.16 M
20
4.32 M
20
4.32 M
100
21.6 M
200
43.2 M
7 h
5
1.26 M
10
2.52 M
20
5.04 M
50
12.6 M
100
25.2 M
8 h
5
1.44 M
10
2.88 M
20
5.76 M
50
14.4 M
100
28.8 M
9 h
5
1.62 M
10
3.24 M
20
6.48 M
50
16.2 M
100
32.4 M
10 h
5
1.8 M
10
3.6 M
20
7.2 M
50
18 M
100
36 M
12 h
5
2.16 M
10
4.32 M
20
8.64 M
50
21.6 M
100
43.2 M
1 day
5
4.32 M
10
8.64 M
20
17.28 M
50
43.2 M
2 days
5
8.64 M
10
17.28 M
20
34.56 M
3 days
5
12.96 M
10
25.92 M
When the time axis setting is 100 ms or greater (the settings surrounded by bold lines) and the trigger mode is Auto or Auto Level,
waveforms are displayed in roll mode.
When the Record Length Is 100 Mpoint, 250 Mpoint, 500 Mpoint, 1 Gpoint, or 2 Gpoint
Record Length
100 Mpoint
250 Mpoint
500 Mpoint
1 Gpoint
2 Gpoint
Time/div Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
100 ns
100 M
100
100 M
100
100 M
100
100 M
100
100 M
100
200 ns
100 M
200
100 M
200
100 M
200
100 M
200
100 M
200
500 ns
100 M
500
100 M
500
100 M
500
100 M
500
100 M
500
1 μs
100 M
1 k
100 M
1 k
100 M
1 k
100 M
1 k
100 M
1 k
2 μs
100 M
2 k
100 M
2 k
100 M
2 k
100 M
2 k
100 M
2 k
5 μs
100 M
5 k
100 M
5 k
100 M
5 k
100 M
5 k
100 M
5 k
10 μs
100 M
10 k
100 M
10 k
100 M
10 k
100 M
10 k
100 M
10 k
20 μs
100 M
20 k
100 M
20 k
100 M
20 k
100 M
20 k
100 M
20 k
50 μs
100 M
50 k
100 M
50 k
100 M
50 k
100 M
50 k
100 M
50 k
100 μs
100 M
100 k
100 M
100 k
100 M
100 k
100 M
100 k
100 M
100 k
200 μs
100 M
200 k
100 M
200 k
100 M
200 k
100 M
200 k
100 M
200 k
500 μs
100 M
500 k
100 M
500 k
100 M
500 k
100 M
500 k
100 M
500 k
1 ms
100 M
1 M
100 M
1 M
100 M
1 M
100 M
1 M
100 M
1 M
2 ms
100 M
2 M
100 M
2 M
100 M
2 M
100 M
2 M
100 M
2 M
5 ms
100 M
5 M
100 M
5 M
100 M
5 M
100 M
5 M
100 M
5 M
10 ms
100 M
10 M
100 M
10 M
100 M
10 M
100 M
10 M
100 M
10 M
20 ms
100 M
20 M
100 M
20 M
100 M
20 M
100 M
20 M
100 M
20 M
50 ms
100 M
50 M
100 M
50 M
100 M
50 M
100 M
50 M
100 M
50 M
100 ms
100 M
100 M
100 M
100 M
100 M
100 M
100 M
100 M
100 M
100 M
200 ms
50 M
100 M
100 M
200 M
100 M
200 M
100 M
200 M
100 M
200 M
500 ms
20 M
100 M
50 M
250 M
100 M
500 M
100 M
500 M
100 M
500 M
1 s
10 M
100 M
20 M
200 M
50 M
500 M
100 M
1 G
100 M
1 G
2 s
5 M
100 M
10 M
200 M
20 M
400 M
50 M
1 G
100 M
2 G
3 s
2 M
60 M
5 M
150 M
10 M
300 M
20 M
600 M
50 M
1.5 G
4 s
2 M
80 M
5 M
200 M
10 M
400 M
20 M
800 M
50 M
2 G
5 s
2 M
100 M
5 M
250 M
10 M
500 M
20 M
1 G
20 M
1 G
6 s
1 M
60 M
2 M
120 M
5 M
300 M
10 M
600 M
20 M
1.2 G
8 s
1 M
80 M
2 M
160 M
5 M
400 M
10 M
800 M
20 M
1.6 G
10 s
1 M
100 M
2 M
200 M
5 M
500 M
10 M
1 G
20 M
2 G
20 s
500 k
100 M
1 M
200 M
2 M
400 M
5 M
1 G
10 M
2 G
30 s
200 k
60 M
500 k
150 M
1 M
300 M
2 M
600 M
5 M
1.5 G
When the time axis setting is 100 ms or greater (the settings surrounded by bold lines) and the trigger mode is Auto or Auto Level,
waveforms are displayed in roll mode.
(Continued on next page)
Appendix 1 Relationship between the Time Axis Setting, Record Length, and Sample Rate