App-5
IM 701510-01E
Appendix
App
Appendix 3
Relationship between the Time Axis
Setting, Sample Rate and Record
Length (for DL1520L/DL1540L)
Displayed record length varies according to the time-axis setting, as omdicated below.
2
5
10
20
50
100
200
500
1k
2k
5k
10k
20k
50k
100k
200k
500k
1M
2M
5M
10M
20M
50M
100M
100M
100M
100M
2G
5G
10G
20G
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
500
200
100
1K
1K
1K
1K
2
5
10
20
50
100
200
500
1k
2k
5k
10k
20k
50k
100k
200k
500k
1M
2M
5M
10M
20M
50M
100M
200M
500M
1G
2G
5G
10G
20G
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
2
5
10
20
50
100
200
500
1k
2k
5k
10k
20k
50k
100k
200k
500k
1M
2M
5M
10M
20M
50M
100M
200M
200M
200M
2G
5G
10G
20G
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
400
200
1K
1K
1K
1K
2
5
10
20
50
100
200
500
1k
2k
5k
10k
20k
50k
100k
200k
500k
1M
2M
5M
10M
20M
50M
100M
200M
500M
1G
2G
5G
10G
20G
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K(2K)
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
100M[1 x 2]
100M[2.5 x 2]
100M[5 x 2]
100M[10 x 2]
100M[25 x 2]
100M[50 x 2]
100M[100 x 2]
100M[250 x 2]
100M[500 x 2]
100M[1k x 2]
100M[2.5k x 2]
100M[5k x 2]
100M[10k x 2]
100M[25k x 2]
100M[50k x 2]
100M[100k x 2]
100M[250k x 2]
100M[500k x 2]
100M[1M x 2]
100M[2.5M x 2]
100M[5M x 2]
100M[10M x 2]
100M[10M x 2]
500 x 2(1K x 2)
500 x 2(1K x 2)
500 x 2(1K x 2)
500 x 2(1K x 2)
500 x 2(1K x 2)
500 x 2(1K x 2)
500 x 2(1K x 2)
500 x 2(1K x 2)
500 x 2(1K x 2)
500 x 2(1K x 2)
500 x 2
500 x 2
500 x 2
500 x 2
500 x 2
500 x 2
500 x 2
500 x 2
500 x 2
500 x 2
500 x 2
500 x 2
200 x 2
T/div
50s
20s
10s
5s
2s
1s
500ms
200ms
100ms
50ms
20ms
10ms
5ms
2ms
1ms
500 s
200 s
100 s
50 s
20 s
10 s
5 s
2 s
1 s
500ns
200ns
100ns
50ns
20ns
10ns
5ns
When "Maximum Displayable Record Length" is set to 1KW
Rep: Repetitive sampling mode
When Mode other than Envelope Mode is Active
At Least One of CH3, CH4 is ON
Rep: "ON"
Rep: "OFF"
Rep: "ON"
Rep: "OFF"
CH3, CH4 are Both OFF
Sample
rate
(S/s)
Displayed
record length
(word)
Sample
rate
(S/s)
Sample
rate
(S/s)
Sample
rate
(S/s)
Displayed
record length
(word)
Displayed
record length
(word)
Displayed
record length
(word)
When Envelope Mode
is Active
Sample
rate
(S/s)
Displayed
record length
(word)
Changes to normal mode,
even when envelope mode
has been set.
*1 The displayed record length given in ( ) refers to the record length stored in the acquisition memory.
Only when the trigger mode is auto or auto level, data of a record length given in ( ) is stored.
In case where no value in ( ) is given, the displayed record length and the record length stored in the acquisition memory
are the same.
*2 The sample rate given in ( ) for the envelope mode is the rate at which data are acquired after having been sampled at
100MS/s and having taken the minimum and maximum values.
*3 In the envelope mode, the minimum / maximum values are displayed in a pair.
*4 For the setting enclosed by the bold line, repetitive sampling mode is active.
*5 CH2 is ON in the case of DL1520L.
*6 CH2 is OFF in the case of DL1520L.
Roll mode display
*5
*6