VS-616G5 Programming Manual
87
V/f
V/f w/PG Open Loop
Vector
Flux
Vector
· Speed Search 3 (Set value = 64)
a = (L2-03) minimum
baseblock time
b = (L2-04) voltage
recovery time
= speed search decel
time
d= V/f pattern reduction
during speed search
Output
Current
Output
Voltage
Motor
RPM
Output
Frequency
Run
Command
Inverter is in
speed search
mode
Inverter is in
run mode
b
c
d
Estimated deceleration
frequency when using
set value 64
a
Speed Search
Command
b3-02
(150%)
Section H: Control Circuit Terminals