140
VS-616G5 Programming Manual
G
ro
up
E
M
ot
or
Fu
nc
tio
n
E3
C
on
tro
l M
et
ho
d
E3-01
Motor 2 Control
Method Selection
(Control Method)
0~3
1
2
0: (V/F Control)
1: (V/F w/PG Fdbk)
2: (Open Loop Vector)
3: (Flux Vector)
x
A
A
A
A
Fu
nc
tio
n
E4
V
/F
P
at
te
rn
2
E4-01
Motor 2 Max. Out-
put Frequency
(Max Frequency)
40.0~
400.0
0.1Hz
60.0
—
x
A
(Note
14)
A
(Note
14)
A
(Note
14)
A
(Note
14)
E4-02
Motor 2 Max.
Voltage
( Max Voltage)
0.0~
255.0
(Note
13)
0.1V
200.0
(Note
13)
—
x
A
(Note
14)
A
(Note
14)
A
(Note
14)
A
(Note
14)
E4-03
Motor 2 Max.
Voltage Frequency
(Base Frequency)
0.0~
400.0
0.1Hz
60.0
—
x
A
(Note
14)
A
(Note
14)
A
(Note
14)
A
(Note
14)
E4-04
Motor 2 Mid.
Output Frequency 1
(Mid Frequency)
0.00~
400.0
0.1Hz
3.0*
* Factory setting differs
depending on the control
method [E3-01]
x
A
(Note
14)
A
(Note
14)
A
(Note
14)
F
(Note
14)
E4-05
Motor 2 Mid.
Output Frequency
Voltage 1
(Mid Voltage)
0.0~
255.0
(Note
13)
0.1V
11.0
(Note
13)*
* Factory setting differs
depending on the control
method [E3-01]
x
A
(Note
14)
A
(Note
14)
A
(Note
14)
F
(Note
14)
E4-06
Motor 2 Min.
Output Frequency
( Min Frequency)
0.0~
400.0
0.1Hz
0.5*
* Factory setting differs
depending on the control
method [E3-01]
x
A
(Note
14)
A
(Note
14)
A
(Note
14)
A
(Note
14)
E4-07
Motor 2 Min.
Output Frequency
Voltage
(Min Voltage)
0.0~
255.0
(Note
13)
0.1V
2.0*
(Note13)
* Factory setting differs
depending on the control
method [E3-01]
x
A
(Note
14)
A
(Note
14)
A
(Note
14)
F
(Note
14)
Note 13: This value is for the 200V class. For 400V class, the value is twice that of 200V class. For 575V class, then modify the values by 575/200
Note 14: Control mode is determined by E3-01.
Function
Parameter
No.
Name
(Digital Operator
Display)
Setting
Range
Setting
Unit
Factory
Setting
Remarks
(Digital Operator Display)
Change
during
Operation
o: Enabled
x: Disabled
Parameter Access Level
User
Setting
V/f
V/f
w/
PG
Open
Loop
Vector
Flux
Vector
Appendix
VS-616G5 Parameter List E Motor