158
VS-616G5 Programming Manual
M
on
ito
r
U1-12
Operation Status*
(Int Ctl Sts 1)
—
—
Q
Q
Q
Q
U1-13
Elapsed Time*
(Elapsed Time)
1 hour
—
—
Q
Q
Q
Q
U1-14
Software No. at FLASH
Side*
(FLASH ID)
—
—
—
Q
Q
Q
Q
U1-15
Control Circuit
Terminal 13
(Term 13 Level)
0.1%
—
10V/10V
B
B
B
B
U1-16
Control Circuit Terminal
14 Input Voltage (Term 14
Level)
0.1%
—
10V/10V or
20 mA
B
B
B
B
U1-17
Control Circuit Terminal
16 Input
(Terminal 16 Level)
0.1%
—
10V/10V
B
B
B
B
U1-18
Motor Secondary
Current (Iq)
(Mot SEC Current)
0.1%
—
10V/Motor
rated
primary
current
B
B
B
B
U1-19
Motor Excitation
Current (Mot EXC Cur-
rent)
0.1%
—
10V/Motor
rated
primary
current
x
x
B
B
U1-20
Output Frequency after
Soft-start
(SFS Output)
0.01Hz
—
10V/Max.
output
frequency
A
A
A
A
U1-21
ASR Input
(ASR Input)
0.01%
—
10V/Max.
output
frequency
x
A
x
A
U1-22
ASR Output
(ASR Output)
0.01%
Analog monitor output level becomes 10V/Max. out-
put frequency for V/f control mode with PG.
10V/Motor
rated
primary
current
x
A
x
A
U1-23
Speed Deviation
(Speed Deviation)
0.01%
—
10V/Max.
output
Frequency
x
A
x
A
U1-24
PID Feedback Capacity
(PID Feedback)
0.01%
–
10V/Max.
output
Frequency
A
A
A
A
Fu
nc
tio
n
Parameter
No.
Name
(Digital Operator Display)
Min.
Unit
Description
Analog
Monitor
Output Level
Parameter Access Level
V/f
V/f w/
PG
Vector
w/o
PG
Vector
w/ PG
1: During running
1: During zero speed
1: During reverse
1: During reset signal input
1: During speed agree
1: Inverter operation ready
1: Minor fault
1: Major fault
0 0 0 0 0 0 0 0
Appendix
VS-616G5 Parameter List U Monitor
* Cannot be changed by U1-04