VS-616G5 Programming Manual
57
V/f
V/f w/PG Open Loop
Vector
Flux
Vector
For 460V class units, the value is twice that of 230V class units. For 575V class units the value is 2.5 times the 230V value.
For 460V class units, the value is twice that of 230V class units. For 575V class units the value is 2.5 times the 230V value.
V/F Patterns for Inverter Capacity 2.2 ~ 45kW for 200V Class
Parameter
No.
Name
Unit
Factory Setting
E1-03
V/f Pattern Selection
—
0
1
2
3
4
5
6
7
E1-04
Max. Output Frequency
Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
E1-05
Max. Voltage
V
230.0
230.0
230.0
230.0
230.0
230.0
230.0
230.0
E1-06
Max. Voltage Frequency
Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
E1-07
Mid. Output Frequency
V
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
E1-08
Mid. Output Frequency Voltage
V
16.1
16.1
16.1
16.1
40.2
57.5
40.2
57.5
E1-09
Min. Output Frequency
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
E1-10
Min. Output Frequency Voltage
V
8.0
8.0
8.0
8.0
6.9
8.0
6.9
8.0
V/F Patterns for Inverter Capacity 2.2 ~ 45kW for 200V Class (Continued)
Parameter
No.
Name
Unit
Factory Setting
E1-03
V/f Pattern Selection
—
8
9
A
B
C
D
E
F
E1-04
Max. Output Frequency
Hz
50.0
50.0
60.0
60.0
90.0
120.0
180.0
60.0
E1-05
Max. Voltage
V
230.0
230.0
230.0
230.0
230.0
230.0
230.0
230.0
E1-06
Max. Voltage Frequency
Hz
50.0
50.0
60.0
60.0
60.0
60.0
60.0
60.0
E1-07
Mid. Output Frequency
V
2.5
2.5
3.0
3.0
3.0
3.0
3.0
3.0
E1-08
Mid. Output Frequency Voltage
V
20.7
26.4
20.7
26.4
16.1
16.1
16.1
16.1
E1-09
Min. Output Frequency
Hz
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.5
E1-10
Min. Output Frequency Voltage
V
10.3
12.6
10.3
14.9
8.0
8.0
8.0
8.0
Section E: Motor Parameters
E1 V/F Pattern