VS-616G5 Programming Manual
7
Menu
Operation
Inverter operation is enabled.
Inverter status is displayed.
A
Initialize
Language selection in LCD display.
Constant access levels, control method
selection and initializing passwords.
Programming
Parameters are set/read. Items to be set/
read vary depending on the access level
setting.
Auto-tuning
Motor parameters are automatically set
by inputting turning data (motor name-
plate values) when performing vector.
Modified Constants
Only parameters that have been changed
from the factory setting are set/read.
U
Monitoring Items
Monitor
B
Application
Application
C
Tuning
Tuning
D
Reference
Reference
E
Motor Parameters
Motor
F
Option
Option
H
Control Circuit Terminals
Terminal
L
Protection
Protection
O
Digital Operator
Operator
Group
Function
Display
Access Level
U1
Status monitoring
Monitor
Q, B, A
U2
Fault trace
Fault Trace
Q
U3
Fault history
Fault History
Q
A1
Initialization
Initialize
Q
A2
User setting parameter
User Parameters
A
B1
Operation method selection
Sequence
Q, B, A
B2
DC injection braking
DC Braking
B
B3
Speed search
Speed Search
A
B4
Timer function
Delay Timers
A
B5
PID control
PID Control
A
B6
DWELL function
Reference Hold
A
B7
Droop control
Droop control
A
B8
Energy-saving control
Energy Saving
A
B9
Zero Servo
Zero Servo
A
C1
Accel/decel time
Accel/Decel
Q, B, A
C2
S-curve characteristics
S-curve Acc/Dec
A
C3
Motor slip compensation
Motor-slip Comp
B. A
C4
Torque compensation
Torque Comp
B, A
C5
ASR
ASR Tuning
B, A
C6
Carrier frequency
Carrier Freq
BA
C7
Hunting prevention
Hunting Prev
A
C8
Factory-tuning constant
Factory Tuning
A
D1
Frequency reference value
Preset Reference
Q, A
D2
Upper/lower limits
Reference Limits
B
D3
Jump frequency
Jump Frequencies
B
D4
Sequence
Sequence
A
D5
Torque reference
Torque Control
A
E1
V/f pattern
V/F Pattern
Q
E2
Motor parameters
Motor Setup
Q, A
E3
Motor 2 control method
Motor 2 Ctl Meth
A
E4
V/f pattern/2
V/f Pattern 2
A
E5
Motor 2 constants
Motor 2 Setup
A
F1
PG speed control card
PG Option setup
Q, B, A
F2
Analog reference card
A1-14 Setup
B
F3
Digital input card
DI-08, 16 Setup
B
F4
Analog monitor card
AO-08, 16 Setup
B
F5
Digital output card
DO-02 Setup
B
F6
Digital output card
DO-08 Setup
B
F7
Pulse monitor card
PO-36F Setup
B
F8
SI-F/G card
SI-F/G
B
F9
DDS-B/SI-B card
DDSS/SI-B
B
H1
Sequence input
Digital Inputs
B
H2
Sequence output
Digital Outputs
B
H3
Analog input
Analog Inputs
B, A
H4
Analog output
Analog Outputs
B
H5
MODBUS communication (RS-485)
Serial Com Setup
A
L1
Motor electric thermal overload relay
Motor Overload
B
L2
Momentary power loss ride-through
PwrLoss Ridethru
B, A
L3
Stall prevention
Stall Prevention
B, A, F
L4
Frequency Detection
Ref Detection
B, A
L5
Fault retry
Fault Restart
B
L6
Overtorque detection
Torque Detection
B, A
L7
Torque limit
Torque Limit
B
L8
Hardware protection
Hdwe Protection
B, A
O1
Display selection
Monitor Select
B, A
O2
Key selection
Key Selections
B, A
VS-616G5 Parameter Tree
VS-616G5 Parameter Tree