3.1 FT82 SERVOPACKs with Analog Voltage/Pulse Train References
3.1.3 Troubleshooting Alarms
3
Maintenance
3-11
A.044:
Semi-Closed/
Fully-Closed
Loop Control
Parameter
Setting Error
The setting of the
Fully-Closed Module
does not match the
setting of Pn002 =
n.X
(External
Encoder Usage).
Check the setting of
Pn002 = n.X
.
Make sure that the setting
of the Fully-closed Mod-
ule agrees with the setting
of Pn002 = n.X
.
*1
A.050:
Combination
Error
(The capacities of
the SERVOPACK
and Servomotor
do not match.)
The SERVOPACK and
Servomotor capaci-
ties do not match
each other.
Confirm that the follow-
ing condition is met:
1/4
≤
(Servomotor
capacity/SERVOPACK
capacity)
≤
4
Select a proper combina-
tion of the SERVOPACK
and Servomotor capaci-
ties.
*1
A failure occurred in
the encoder.
Replace the encoder
and check to see if the
alarm still occurs.
Replace the Servomotor
or encoder.
–
A failure occurred in
the SERVOPACK.
–
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
–
A.051:
Unsupported
Device Alarm
An unsupported Serial
Converter Unit or
encoder (e.g., an
external encoder) is
connected to the
SERVOPACK.
Check the product
combination specifica-
tions.
Change to a correct com-
bination of models.
–
A.0b0:
Invalid Servo ON
Command Alarm
The /S-ON (Servo ON)
signal was input from
the host controller
after a utility function
that turns ON the Ser-
vomotor was exe-
cuted.
–
Turn the power supply to
the SERVOPACK OFF and
ON again. Or, execute a
software reset.
*1
Continued on next page.
Continued from previous page.
Alarm Number:
Alarm Name
Possible Cause
Confirmation
Correction
Reference