4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
4-162
Pn512
2
Output Signal Inverse
Settings
0000h to
1111h
–
0000h
All
After
restart
Setup
–
Pn513
2
Output Signal Inverse
Settings 2
0000h to
0011h
–
0000h
All
After
restart
Setup
–
Continued on next page.
Pn514
2
Output Signal Selec-
tions 4
0000h to
0666h
–
0000h
All
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Output Signal Inversion for CN1-25 and CN1-26 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-27 and CN1-28 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-29 and CN1-30 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.X
Output Signal Inversion for CN1-37 Terminal
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-38 Terminal
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-39 Terminal
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
/PM (Preventative Maintenance Output) Signal Allocation
Reference
0
Disabled (the above signal output is not used).
*1
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
n.X
Reserved parameter (Do not change.)