![YASKAWA SGM7D-01G Скачать руководство пользователя страница 426](http://html.mh-extra.com/html/yaskawa/sgm7d-01g/sgm7d-01g_product-manual_907683426.webp)
4.3 FT82 SERVOPACK with MECHATROLINK-III Communications References
4.3.1 List of Servo Parameters
4
Parameter Li
s
t
s
4-101
Pn83C
4
Second Stage Linear
Deceleration Constant 2
1 to
20,971,520
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*12
Setup
*2
Pn83E
4
Deceleration Constant
Switching Speed 2
0 to
2,097,152,000
1 refer-
ence
unit/s
0
All
Immedi-
ately
*12
Setup
*2
Pn840
4
Linear Deceleration
Constant 2 for Stopping
1 to
20,971,520
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*12
Setup
*2
Pn842
*16
4
Second Origin
Approach Speed 1
0 to
20,971,520
100 ref-
erence
units/s
0
All
Immedi-
ately
*12
Setup
*2
Pn844
*17
4
Second Origin
Approach Speed 2
0 to
20,971,520
100 ref-
erence
units/s
0
All
Immedi-
ately
*12
Setup
*2
Pn846
2
POSING Command
Scurve Acceleration/
Deceleration Rate
0 to 50
1%
0
All
Immedi-
ately
*12
Setup
–
Pn850
2
Number of Latch
Sequences
0 to 8
–
0
All
Immedi-
ately
Setup
*2
Pn851
2
Continuous Latch
Sequence Count
0 to 255
–
0
All
Immedi-
ately
Setup
*2
Pn852
2
Latch Sequence 1 to 4
Settings
0000h to
3333h
–
0000h
All
Immedi-
ately
Setup
*2
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Latch Sequence 1 Signal Selection
0
Phase C
1
EXT1 signal
2
EXT2 signal
3
EXT3 signal
n.
X
Latch Sequence 2 Signal Selection
0 to 3
The settings are the same as those for the Latch Sequence 1 Signal Selec-
tion.
n.
X
Latch Sequence 3 Signal Selection
0 to 3
The settings are the same as those for the Latch Sequence 1 Signal Selec-
tion.
n.X
Latch Sequence 4 Signal Selection
0 to 3
The settings are the same as those for the Latch Sequence 1 Signal Selec-
tion.