4.3 FT82 SERVOPACK with MECHATROLINK-III Communications References
4.3.1 List of Servo Parameters
4-68
Pn002
2
Application Function
Selections 2
0000h to
4213h
–
0011h
–
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
MECHATROLINK Command Position and Speed Control
Option
Applicable
Motors
Reference
0
Reserved setting (Do not use.)
All
*2
1
Use TLIM as the torque limit.
2
Reserved setting (Do not use.)
3
Reserved setting (Do not use.)
n.
X
Torque Control Option
Applicable
Motors
Reference
0
Reserved setting (Do not use.)
All
*2
1
Use the speed limit for torque control (VLIM) as the
speed limit.
n.
X
Encoder Usage
Applicable
Motors
Reference
0
Use the encoder according to encoder specifica-
tions.
All
*1
1
Use the encoder as an incremental encoder.
2
Use the encoder as a single-turn absolute
encoder.
Rotary
n.X
External Encoder Usage
Applicable
Motors
Reference
0
Do not use an external encoder.
Rotary
*1
1
The external encoder moves in the forward direc-
tion for CCW motor rotation.
2
Reserved setting (Do not use.)
3
The external encoder moves in the reverse direc-
tion for CCW motor rotation.
4