3.3 FT82 SERVOPACK with MECHATROLINK-III Communications References
3.3.2 List of Alarms
3-100
A.7A2
Internal Temperature Error
2 (Power Board Tempera-
ture Error)
The surrounding temperature of the power PCB
is abnormal.
Gr.2
Yes
A.7A3
Internal Temperature Sen-
sor Error
An error occurred in the temperature sensor cir-
cuit.
Gr.2
No
A.7Ab
SERVOPACK Built-in Fan
Stopped
The fan inside the SERVOPACK stopped.
Gr.1
Yes
A.810
Encoder Backup Alarm
The power supplies to the encoder all failed and
the position data was lost.
Gr.1
No
A.820
Encoder Checksum Alarm
There is an error in the checksum results for
encoder memory.
Gr.1
No
A.830
Encoder Battery Alarm
The battery voltage was lower than the specified
level after the control power supply was turned
ON.
Gr.1
Yes
A.840
Encoder Data Alarm
There is an internal data error in the encoder.
Gr.1
No
A.850
Encoder Overspeed
The encoder was operating at high speed when
the power was turned ON.
Gr.1
No
A.860
Encoder Overheated
The internal temperature of encoder is too high.
Gr.1
No
A.861
Motor Overheated
The internal temperature of motor is too high.
Gr.1
No
A.862
Overheat Alarm
The input voltage (temperature) for the overheat
protection input (TH) signal exceeded the setting
of Pn61B (Overheat Alarm Level).
Gr.1
Yes
A.8A0
External Encoder Error
An error occurred in the external encoder.
Gr.1
Yes
A.8A1
External Encoder Module
Error
An error occurred in the Serial Converter Unit.
Gr.1
Yes
A.8A2
External Incremental
Encoder Sensor Error
An error occurred in the external encoder.
Gr.1
Yes
A.8A3
External Absolute Encoder
Position Error
An error occurred in the position data of the
external encoder.
Gr.1
Yes
A.8A5
External Encoder Over-
speed
An overspeed error occurred in the external
encoder.
Gr.1
Yes
A.8A6
External Encoder Over-
heated
An overheating error occurred in the external
encoder.
Gr.1
Yes
A.b33
Current Detection Error 3
An error occurred in the current detection circuit.
Gr.1
No
A.b6A
MECHATROLINK Commu-
nications ASIC Error 1
ASIC error 1 occurred in MECHATROLINK com-
munications.
Gr.1
No
A.b6b
MECHATROLINK Commu-
nications ASIC Error 2
ASIC error 2 occurred in MECHATROLINK com-
munications.
Gr.2
No
A.bF0
System Alarm 0
Internal program error 0 occurred in the SERVO-
PACK.
Gr.1
No
A.bF1
System Alarm 1
Internal program error 1 occurred in the SERVO-
PACK.
Gr.1
No
A.bF2
System Alarm 2
Internal program error 2 occurred in the SERVO-
PACK.
Gr.1
No
A.bF3
System Alarm 3
Internal program error 3 occurred in the SERVO-
PACK.
Gr.1
No
A.bF4
System Alarm 4
Internal program error 4 occurred in the SERVO-
PACK.
Gr.1
No
A.bF5
System Alarm 5
Internal program error 5 occurred in the SERVO-
PACK.
Gr.1
No
A.bF6
System Alarm 6
Internal program error 6 occurred in the SERVO-
PACK.
Gr.1
No
Continued on next page.
Continued from previous page.
Alarm
Number
Alarm Name
Alarm Meaning
Servo-
motor
Stop-
ping
Method
Alarm
Reset
Possi-
ble?