3.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
3.5.4 INDEXER Alarm Displays and Troubleshooting
3-236
*1.
These alarms can be reset, but a Canceled Program Table Error (E44E) will occur the next time you attempt to
start program table operation, so program table operation will not be possible.
*2.
These alarms can be reset, but it is possible that the zone signals (POUT0 to POUT4) will be output incorrectly.
When using the zone table, correct the zone table without resetting.
*3.
These alarms can be reset, but a Canceled JOG Speed Table Error (E46E) will occur the next time you attempt
to start JOG speed table operation, so JOG speed table operation will not be possible.
E1DA
A.EF9
ZONE Table
Version
Unmatched
(Detected only
when the control
power supply is
turned ON.)
The combination of
the firmware version
and the ZONE table
version is wrong.
•
Change the firm-
ware version.
•
Change the ZONE
table version to
match the firmware
version.
Gr.1
Available
*2
E1EA
A.EF9
Zone Table Out-
of-range Alarm
(Detected only
when control
power supply is
turned ON.)
A value set in the
zone table is not
within the allowed
setting range.
•
Change the firm-
ware version.
•
Change the ZONE
table version to
match the firmware
version.
Gr.1
Available
*2
E1FA
A.EF9
JOG Speed
Table Check-
sum Alarm
(Detected only
when control
power supply is
turned ON.)
The JOG speed
table stored in flash
memory was not
recorded properly.
(This alarm can
occur if the control
power supply is
turned OFF while the
JOG speed table is
being saved or ini-
tialized.)
•
Initialize the JOG
speed table. (Fn065)
•
If the problem is not
solved, correct the
JOG speed table.
Gr.1
Available
*3
E21A
A.EF9
JOG Speed
Table Version
Unmatched
(Detected only
when the control
power supply is
turned ON.)
The combination of
the firmware version
and the JOG speed
table version is
wrong.
•
Change the firm-
ware version.
•
Change the JOG
speed table version
to match the firm-
ware version.
Gr.1
Available
*3
E22A
A.EF9
JOG Speed
Table Out-of-
range Alarm
(Detected only
when control
power supply is
turned ON.)
A value set in the
JOG speed table is
not within the
allowed setting
range.
•
Change the firm-
ware version.
•
Change the JOG
speed table version
to match the firm-
ware version.
Gr.1
Available
*3
E23A
A.EF9
Insufficient Reg-
istration Dis-
tance Alarm
The registration dis-
tance was shorter
than the decelera-
tion distance when
the /RGRT signal
went ON to start
registration opera-
tion. (The current
position will exceed
the position speci-
fied by registration.)
Either increase the
registration distance
or reduce the deceler-
ation distance
(increase the deceler-
ation rate).
Registration dis-
tance: RDST in the
program table
Deceleration Rate:
Pn640
Gr.1
Available
Continued from previous page.
Error
Number
Alarm
Number
Alarm Name
Meaning
Corrective Action
Servo-
motor
Stop
Method
Alarm
Reset