3.4 Command Option Attachable-type FT82 SERVOPACKs with INDEXER Modules
3.4.4 INDEXER Module Alarm Displays and Troubleshooting
3-180
*1.
These alarms can be reset, but a Canceled Program Table Error (E44E) will occur the next time you attempt to
start program table operation, so program table operation will not be possible.
*2.
These alarms can be reset, but it is possible that the zone signals (POUT0 to POUT7) will be output incorrectly.
When using the zone table, correct the zone table without resetting.
*3.
These alarms can be reset, but a Canceled JOG Speed Table Error (E46E) will occur the next time you attempt
to start JOG speed table operation, so JOG speed table operation will not be possible.
E22A
A.AEF
JOG Speed
Table Out-of-
range Alarm
(Detected only
when control
power supply is
turned ON.)
A value set in the
JOG speed table is
not within the
allowed setting
range.
•
Change the firm-
ware version.
•
Change the JOG
speed table version
to match the firm-
ware version.
Gr.1
Available
*3
E23A
A.AEF
Insufficient Reg-
istration Dis-
tance Alarm
The registration dis-
tance was shorter
than the decelera-
tion distance when
the /RGRT signal
went ON to start
registration opera-
tion. (The current
position will exceed
the position speci-
fied by registration.)
Either increase the
registration distance
or reduce the deceler-
ation distance
(increase the deceler-
ation rate).
The registration dis-
tance can be set by
executing the RDST
command or chang-
ing the RDST param-
eter in the program
table.
The deceleration rate
can be changed by
executing the DEC
command or chang-
ing parameter PnB2B.
Gr.1
Available
Continued from previous page.
Serial
Command
Negative
Response
Alarm
Number
Alarm Name
Meaning
Corrective Action
Servo-
motor
Stop
Method
Alarm
Reset