4.1 FT82 SERVOPACKs with Analog Voltage/Pulse Train References
4
Parameter Li
s
t
s
4-15
Pn20A
4
Number of External
Encoder Scale Pitches
4 to
1,048,576
1 scale
pitch/
revolu-
tion
32768
Rotary
After
restart
Setup
*1
Pn20E
4
Electronic Gear Ratio
(Numerator)
1 to
1,073,741,824
1
64
All
After
restart
Setup
*1
Pn210
4
Electronic Gear Ratio
(Denominator)
1 to
1,073,741,824
1
1
All
After
restart
Setup
*1
Pn212
4
Number of Encoder
Output Pulses
16 to
1,073,741,824
1 P/Rev
2048
Rotary
After
restart
Setup
*1
Pn216
2
Position Reference
Acceleration/Decelera-
tion Time Constant
0 to 65,535
0.1 ms
0
All
Immedi-
ately after
the motor
stops
Setup
*1
Pn217
2
Average Position Refer-
ence Movement Time
0 to 10,000
0.1 ms
0
All
Immedi-
ately after
the motor
stops
Setup
*1
Pn218
2
Reference Pulse Input
Multiplier
1 to 100
×
1
1
All
Immedi-
ately
Setup
*1
Pn22A
2
Fully-closed Control
Selections
0000h to
1003h
–
0000h
Rotary
After
restart
Setup
*1
Pn281
2
Encoder Output Resolu-
tion
1 to 4,096
1 edge/
pitch
20
All
After
restart
Setup
*1
Pn300
2
Speed Reference Input
Gain
150 to 3,000
0.01 V/
Rated
motor
speed
600
All
Immedi-
ately
Setup
*1
Pn301
2
Internal Set Speed 1
0 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1
min
-1
100
Rotary
Immedi-
ately
Setup
*1
Pn302
2
Internal Set Speed 2
0 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1
min
-1
200
Rotary
Immedi-
ately
Setup
*1
Pn303
2
Internal Set Speed 3
0 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1
min
-1
300
Rotary
Immedi-
ately
Setup
*1
Pn304
2
Jogging Speed
0 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1
min
-1
500
Rotary
Immedi-
ately
Setup
*1
Pn305
2
Soft Start Acceleration
Time
0 to 10,000
1 ms
0
All
Immedi-
ately
Setup
*1
Pn306
2
Soft Start Deceleration
Time
0 to 10,000
1 ms
0
All
Immedi-
ately
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Fully-closed Control Speed Feedback Selection
0
Use motor encoder speed.
1
Use external encoder speed.